Tag Archives: compressor switch pressure switch control

Coolsour Differential Low Air Compressor Automatic Pressure Control Switch

Coolsour Differential Low Air Compressor Automatic Pressure Control Switch

Stress Controller-S/D Sequence

Description:
one.For use with fluorinated refrigerants as well as with air and liquid(Allowable fluid temp.:-45ºC~+120ºC)
2.A variety of make contact with capabilities offered,with SPDT make contact with mechanism
three.Renovated micro-swith structure assures the dependable swap operate
4.Manual-managed and no use of other devices to have a function check
5.Versatile mounting plate fits numerous sorts of application
six.1/4,G1/4,capillary or specific connetion can be accessible and make sure you advise us when positioning get.

 

Type Pressure   Pressure range  (Mpa)   CZPTential range  (Mpa)   Factory Setting   (Mpa) Max.Bellows Pressure (Mpa)
Min. Max. Min. Max. OFF ON
S103X Minimal -.06 .3 .035 .two .05 .fifteen 1.sixty five
S106X Reduced -.06 .6 .06 .4 .two .three one.sixty five
S110X Minimal .1 1 .one .3 .4 .6 1.sixty five
S120X Substantial .five two .two .5 1.five one.two 4
D306X Dual L-H Low side -.06 .6 .06 .four .two .3 one.65
High side .eight three Fixed 0.four Fixed 0.4 2 1.6 four
D606X Dual L-H Low side -.06 .6 .06 .4 .two .3 one.sixty five
High side .8 three Fixed 0.four Fixed 0.4 2 one.six 4
D306XM Dual L-H Low side -.06 .six .06 .4 .two .3 1.65
High side .eight three pressure Rise-auto reset pressure Fall-manual reset two Manual Reset four
D606XM Dual L-H Low side -.06 .6 .06 .four .2 .3 1.65
High side .eight 3 pressure Rise-auto reset pressure Fall-manual reset 2 Manual Reset four
D606XMM Dual L-H Low side -.06 .6 pressure Rise-auto reset pressure Fall-manual reset .two Manual Reset one.65
High side .eight three pressure Rise-auto reset pressure Fall-manual reset two Manual Reset 4

Force Controller-HLP Sequence

Description:
one.For use with fluorinated refrigerants as well as with air and liquid(Allowable fluid temp.:-45ºC~+120ºC) 
two.Various contact functions available,with SPDT contact mechanism
3.Renovated micro-swith structure ensures the reliable switch function
4.Handbook-controlled and no use of other instruments to have a function test
5.Flexible mounting plate suits various kinds of application
6.1/four,G1/4,capillary or special connetion can be available and please inform us when placing order.

Sort Stress   Pressure range  (Bar)   CZPTential range  (Mpa)   Factory Setting   (Mpa) Max.Bellows Pressure (Mpa)
Min. Max. Min. Max. OFF ON
HLP502 Lower .25 1.five .2 1 one .5 sixteen.5
HLP503 Reduced -.7 3 .five 1.five 2 1
HLP506 Reduced -.seven 6 .5 three 3 2
HLP506M Reduced -.7 six Reset differential≤1 three manual reset
HLP110 Reduced 1 10 one 3 six five
HLP516 High five sixteen one 4 ten 8 35
HLP520 Higher 5 24 2 five sixteen thirteen
HLP530D Large five thirty 5 10 twenty fifteen
HLP530 Large 8 30 Fixed 3-five twenty 15
HLP530M Higher 8 30 Reset differential≥4 20 manual reset
HLP830 Dual L-H Low side -.7 six .6 4 three 2 16.five
High side 8 30 Fixed 3-5 20 15 35
HLP830HM Dual L-H Low side -.7 six .6 4 three two sixteen.5
High side eight thirty Reset differential≥4 twenty manual reset 35
HLP830HLM Twin L-H Low side -.7 six Reset differential≤1 3 manual reset sixteen.five
High side eight 30 Reset differential≥4 20 manual reset 35

Stress Controller – P Sequence

Description:
one.Pressure contorl is used to protect refrigeration or airconditioning equipment from breathing pressure higheror exhausting lower in system of refrigeration compressor
2.Pressure contorl is also used in the start & stop of the refrigeration compressors and air-cooled condenser fans
3.With SPDT contact mechanism, allowable fluid Temp.:-10ºC~+110ºC
four.Handbook-control and no use of other instruments to have a function tests.

Product Pressure  Low Pressure(LP) High Pressure(HP) Reset Contact System
one/four” Flare one/4″ Solder Adjust Range CZPTential 
Stress
Adjust Range CZPTential 
Strain
Low Pressure
(LP)
High Pressure
(HP)
(bar) (bar) (bar) (bar)
PL1A PL1AS Reduced -.2 → 7.5 .7 → 4.     Vehicle   SPDT
PL1M PL1MS Reduced -.9 → 7. Fixed 0.seven     Guide  
PL2A PL2AS Low -.2 → 5. .4 → 1.5     Car  
PH5A PH5AS Higher     8 → 32 1.8 →6.   Vehicle
PH5M PH5MS High     8 → 32 Fixed 3   Guide
PD15AA PD15AAS Dual -.2 → 7.five .7 → 4. 8 → 32 Fixed 4 Automobile Vehicle SPDT+Low Signal
PD15AM PD15AMS Dual -.2 → 7.five .7 → 4. 8 → 32 Fixed 4 Vehicle Manual
PD15MM PD15MMS Dual -.9 → 7. Fixed 0.seven 8 → 32 Fixed 4 Guide Guide
PD15AAD PD15AADS Twin -.2 → 7.5 .7 → 4. 8 → 32 Fixed 4 Auto Auto SPDT+Low& high Signal
PD15AMD PD15AMDS Twin -.2 → 7.five .7 → 4. 8 → 32 Fixed 4 Automobile Guide
PL35A PL35AS Low  -.2 → 7.5 .7 → 4.     Vehicle   SPDT
PL36A PL36AS Low  2 → 14 .7 → 4.     Car  
PH38A PH38AS Higher     8 → 32 one.8 →6.   Vehicle

CZPTential Pressure Change

Description:
one.For use with fluorinated refrigerants as well as with air and liquid(Allowable fluid temp.:-45ºC~+120ºC) 
2.CZPTential pressure of the pressure control is asdjustalbe
3.Novel micro-switch ensures reliable switching
four.Mounting bracket is suitable for different occasions
5.It can be used  as protective devices for maintaining oil pressure of compressor for air-conditioning purpose
six.Two pattern: with or without time delay, delay time 60,90,120 CZPTs can be available
7.1/four,G1/4,capillary or special connetion can be available and please inform us when order.

Sort   Adjust range   ( bar) Factory setting differential     ( bar) Reset time(sec.) Max bellows Pressure
 ( bar)
HLD1.5C .3~1.five .three without having 17
HLD2C .three~two .five without seventeen
HLD4C .5~four one with no seventeen
HLD4H 2~four two without having 33
HLD6H 2~6 two without having 33
HLD2TC .3~2 .5 60,ninety,a hundred and twenty 17
HLD4TC .five~four 1 sixty,90,120 seventeen
HLD4TH 2~4 2 60,90,120 33
HLD6TH 2~6 two 60,90,a hundred and twenty 33

 

Coolsour Differential Low Air Compressor Automatic Pressure Control Switch