Stress Controller-S/D Sequence
Description:
one.For use with fluorinated refrigerants as well as with air and liquid(Allowable fluid temp.:-45ºC~+120ºC)
2.A variety of make contact with capabilities offered,with SPDT make contact with mechanism
three.Renovated micro-swith structure assures the dependable swap operate
4.Manual-managed and no use of other devices to have a function check
5.Versatile mounting plate fits numerous sorts of application
six.1/4,G1/4,capillary or specific connetion can be accessible and make sure you advise us when positioning get.
Type | Pressure | Pressure range (Mpa) | CZPTential range (Mpa) | Factory Setting (Mpa) | Max.Bellows Pressure (Mpa) | ||||
Min. | Max. | Min. | Max. | OFF | ON | ||||
S103X | Minimal | -.06 | .3 | .035 | .two | .05 | .fifteen | 1.sixty five | |
S106X | Reduced | -.06 | .6 | .06 | .4 | .two | .three | one.sixty five | |
S110X | Minimal | .1 | 1 | .one | .3 | .4 | .6 | 1.sixty five | |
S120X | Substantial | .five | two | .two | .5 | 1.five | one.two | 4 | |
D306X | Dual L-H | Low side | -.06 | .6 | .06 | .four | .two | .3 | one.65 |
High side | .eight | three | Fixed 0.four | Fixed 0.4 | 2 | 1.6 | four | ||
D606X | Dual L-H | Low side | -.06 | .6 | .06 | .4 | .two | .3 | one.sixty five |
High side | .8 | three | Fixed 0.four | Fixed 0.4 | 2 | one.six | 4 | ||
D306XM | Dual L-H | Low side | -.06 | .six | .06 | .4 | .two | .3 | 1.65 |
High side | .eight | three | pressure Rise-auto reset | pressure Fall-manual reset | two | Manual Reset | four | ||
D606XM | Dual L-H | Low side | -.06 | .6 | .06 | .four | .2 | .3 | 1.65 |
High side | .eight | 3 | pressure Rise-auto reset | pressure Fall-manual reset | 2 | Manual Reset | four | ||
D606XMM | Dual L-H | Low side | -.06 | .6 | pressure Rise-auto reset | pressure Fall-manual reset | .two | Manual Reset | one.65 |
High side | .eight | three | pressure Rise-auto reset | pressure Fall-manual reset | two | Manual Reset | 4 |
Force Controller-HLP Sequence
Description:
one.For use with fluorinated refrigerants as well as with air and liquid(Allowable fluid temp.:-45ºC~+120ºC)
two.Various contact functions available,with SPDT contact mechanism
3.Renovated micro-swith structure ensures the reliable switch function
4.Handbook-controlled and no use of other instruments to have a function test
5.Flexible mounting plate suits various kinds of application
6.1/four,G1/4,capillary or special connetion can be available and please inform us when placing order.
Sort | Stress | Pressure range (Bar) | CZPTential range (Mpa) | Factory Setting (Mpa) | Max.Bellows Pressure (Mpa) | ||||
Min. | Max. | Min. | Max. | OFF | ON | ||||
HLP502 | Lower | .25 | 1.five | .2 | 1 | one | .5 | sixteen.5 | |
HLP503 | Reduced | -.7 | 3 | .five | 1.five | 2 | 1 | ||
HLP506 | Reduced | -.seven | 6 | .5 | three | 3 | 2 | ||
HLP506M | Reduced | -.7 | six | Reset differential≤1 | three | manual reset | |||
HLP110 | Reduced | 1 | 10 | one | 3 | six | five | ||
HLP516 | High | five | sixteen | one | 4 | ten | 8 | 35 | |
HLP520 | Higher | 5 | 24 | 2 | five | sixteen | thirteen | ||
HLP530D | Large | five | thirty | 5 | 10 | twenty | fifteen | ||
HLP530 | Large | 8 | 30 | Fixed 3-five | twenty | 15 | |||
HLP530M | Higher | 8 | 30 | Reset differential≥4 | 20 | manual reset | |||
HLP830 | Dual L-H | Low side | -.7 | six | .6 | 4 | three | 2 | 16.five |
High side | 8 | 30 | Fixed 3-5 | 20 | 15 | 35 | |||
HLP830HM | Dual L-H | Low side | -.7 | six | .6 | 4 | three | two | sixteen.5 |
High side | eight | thirty | Reset differential≥4 | twenty | manual reset | 35 | |||
HLP830HLM | Twin L-H | Low side | -.7 | six | Reset differential≤1 | 3 | manual reset | sixteen.five | |
High side | eight | 30 | Reset differential≥4 | 20 | manual reset | 35 |
Stress Controller – P Sequence
Description:
one.Pressure contorl is used to protect refrigeration or airconditioning equipment from breathing pressure higheror exhausting lower in system of refrigeration compressor
2.Pressure contorl is also used in the start & stop of the refrigeration compressors and air-cooled condenser fans
3.With SPDT contact mechanism, allowable fluid Temp.:-10ºC~+110ºC
four.Handbook-control and no use of other instruments to have a function tests.
Product | Pressure | Low Pressure(LP) | High Pressure(HP) | Reset | Contact System | ||||
one/four” Flare | one/4″ Solder | Adjust Range | CZPTential Stress |
Adjust Range | CZPTential Strain |
Low Pressure (LP) |
High Pressure (HP) |
||
(bar) | (bar) | (bar) | (bar) | ||||||
PL1A | PL1AS | Reduced | -.2 → 7.5 | .7 → 4. | Vehicle | SPDT | |||
PL1M | PL1MS | Reduced | -.9 → 7. | Fixed 0.seven | Guide | ||||
PL2A | PL2AS | Low | -.2 → 5. | .4 → 1.5 | Car | ||||
PH5A | PH5AS | Higher | 8 → 32 | 1.8 →6. | Vehicle | ||||
PH5M | PH5MS | High | 8 → 32 | Fixed 3 | Guide | ||||
PD15AA | PD15AAS | Dual | -.2 → 7.five | .7 → 4. | 8 → 32 | Fixed 4 | Automobile | Vehicle | SPDT+Low Signal |
PD15AM | PD15AMS | Dual | -.2 → 7.five | .7 → 4. | 8 → 32 | Fixed 4 | Vehicle | Manual | |
PD15MM | PD15MMS | Dual | -.9 → 7. | Fixed 0.seven | 8 → 32 | Fixed 4 | Guide | Guide | |
PD15AAD | PD15AADS | Twin | -.2 → 7.5 | .7 → 4. | 8 → 32 | Fixed 4 | Auto | Auto | SPDT+Low& high Signal |
PD15AMD | PD15AMDS | Twin | -.2 → 7.five | .7 → 4. | 8 → 32 | Fixed 4 | Automobile | Guide | |
PL35A | PL35AS | Low | -.2 → 7.5 | .7 → 4. | Vehicle | SPDT | |||
PL36A | PL36AS | Low | 2 → 14 | .7 → 4. | Car | ||||
PH38A | PH38AS | Higher | 8 → 32 | one.8 →6. | Vehicle |
CZPTential Pressure Change
Description:
one.For use with fluorinated refrigerants as well as with air and liquid(Allowable fluid temp.:-45ºC~+120ºC)
2.CZPTential pressure of the pressure control is asdjustalbe
3.Novel micro-switch ensures reliable switching
four.Mounting bracket is suitable for different occasions
5.It can be used as protective devices for maintaining oil pressure of compressor for air-conditioning purpose
six.Two pattern: with or without time delay, delay time 60,90,120 CZPTs can be available
7.1/four,G1/4,capillary or special connetion can be available and please inform us when order.
Sort | Adjust range ( bar) | Factory setting differential ( bar) | Reset time(sec.) | Max bellows Pressure ( bar) |
||
HLD1.5C | .3~1.five | .three | without having | 17 | ||
HLD2C | .three~two | .five | without | seventeen | ||
HLD4C | .5~four | one | with no | seventeen | ||
HLD4H | 2~four | two | without having | 33 | ||
HLD6H | 2~6 | two | without having | 33 | ||
HLD2TC | .3~2 | .5 | 60,ninety,a hundred and twenty | 17 | ||
HLD4TC | .five~four | 1 | sixty,90,120 | seventeen | ||
HLD4TH | 2~4 | 2 | 60,90,120 | 33 | ||
HLD6TH | 2~6 | two | 60,90,a hundred and twenty | 33 |