CZPT Oil-Injected Rotary CZPT CZPTs
CWD seven-four hundred & CWD 7-400 PM
Energy output: 7-400 kW / ten-five hundred hp
Supply charge: .eight-71.two m3/min / 28-2514 cfm
Pressure assortment: seven-thirteen bar / one hundred-190 psig
CZPT CZPT – Greatest STHangZhouRD
SIMPLICITY BUT NOT Straightforward
For three generations, buyers from mechanical engineering, market and trade have relied on CZPT know-how when it arrives to plHangZhou, creating and producing compressed air programs. They are totally conscious of the simple fact that CZPT AIR is a lot more than just normal compressed air: utmost protection, excellent performance, excellent quality, maximized overall flexibility together with dependable service are the elements to transform CZPT AIR into air to operate with – in China, in Asia and in far more than 102 nations around the globe.
The III technology, the basis for affordable compressed air creation
The Know-How
Much more than many years of know-how in production for the compressed air market place. Planet vast expertise in diverse compressed air apps have guided the growth of consumer specified stationary screw compressors.
CZPT Development for your Reward
The benefit of CZPT lies in its simplified development. Fewer elements are used. This means a 60% reduction in principal and putting on parts and more than 70% less pipes and connections. In turn, this tremendously reduces the danger of leakages, making the technique environmentally pleasant. Secure immediate push procedure with out V-belt transmission.
The CZPT CZPT CZPT performs in the pursuing way:
Ambient air is drawn by way of the ingestion filter and the multifunctional management system into the screw compressor block. This block consists of a pair of screw rotors. The primary rotor, driven by an electric motor, will take the CZPTary rotor with it. The air is drawn in by the rotation of the two of the interlocking rotors and is continually compressed. During rotation, coolant is injected into the rotors and varieties a hydrostatic movie in between the primary and CZPTary rotors. The perform of the coolant is to seal the rotors, lubricate the bearings and adsorb the compression heat. Prior to compressed air leaves the compressor ( at eighty ºC approx.) it is divided from the coolant before becoming cooled in the aftercooler to approx.. 8ºC to 12ºC earlier mentioned the ambient temperature. The coolant then passes to the thermostatic handle block and filter, ahead of coming into the cooler in which it is cooled from approx.. 80ºC down to 50ºC. It is then injected again into the screw compressor block.
Features:
Immediate travel by means of adaptable coupling.
Completely encapsulated CZPT screw compressor block.
Regular electric powered motor CZPT Index IP23 and IP54.
Consumer friendly service access.
Leading high quality, washable, oil resistant audio insulation.
Ready for procedure, prewired and fully enclosed.
With operating method selector swap CZPT-Off-Ongoing.
Centrally mounted cooling fan offered for compressed air and lubricant coolers.
Compact and neat cupboard design and style.
Optional CZPT:
Sense of rotation
Multiple unit control with automated base load choice
Full motor security
Mains isolator switch for wall mounting
CZPT these features we offer you a vast choice of compressed air add-ons in reference to our compressor item variety.
CZPT Restoration Methods CZPT-THERM
Compressed Air CZPTs
Compressed Air Dryers
Condensate Traps
Oil-Water Separators
Compressed Air Receivers
CZPT OIL-INJECTED Long lasting MAGNET Variable Speed CZPT
Complex Specs CWD seven-400 PM
(7.5-400kW / ten-500hp)
Design | Motor Power kW / hp |
Free of charge Air Shipping m3/min |
Sounds Stage dB(A) |
Dimension L * W * H mm |
Excess weight Kg |
||||
7barg | 8barg | 10barg | 13barg | ||||||
CWD7 PM | 7.5 / ten | one.3 | 1.2 | 1. | .eight | 66 | 760*seven-hundred*920 | two hundred | |
CWD11 PM | eleven / 15 | 1.7 | 1.six | 1.four | one.2 | 68 | 980*750*1000 | 350 | |
CWD15 PM | 15 / 20 | 2.5 | 2.three | 2.one | 1.nine | sixty eight | 980*750*1000 | 360 | |
CWD18 PM | 18.five / twenty five | 3.2 | 3. | two.seven | two.four | 68 | 1120*850*1160 | five hundred | |
CWD22 PM | 22 / thirty | 3.8 | 3.6 | 3.two | 2.8 | sixty eight | 1120*850*1160 | 520 | |
CWD30 PM | thirty / forty | five.3 | 5. | 4.5 | 4. | sixty eight | 1120*850*1160 | 550 | |
CWD37 PM | 37 / 50 | 6.eight | 6.two | 5.6 | five. | sixty eight | 1280*one thousand*1290 | 750 | |
CWD45 PM | forty five / 60 | eight. | seven.three | 7. | 5.nine | 72 | 1280*a thousand*1290 | 780 | |
CWD55 PM | fifty five / seventy five | ten.one | nine.five | eight.7 | 7.eight | 72 | 1800*1230*1570 | 1600 | |
CWD75 PM | 75 / 100 | thirteen.6 | 12.8 | 12.3 | ten.2 | 72 | 1800*1230*1570 | 1800 | |
CWD90 PM | ninety / 125 | 16.2 | 15.five | 14. | twelve.five | 72 | 1800*1230*1570 | 1900 | |
CWD110 PM | one hundred ten / one hundred fifty | 21.two | 19.8 | seventeen.8 | 15.five | 72 | 2400*1470*1840 | 2500 | |
CWD132 PM | 132 / one hundred eighty | 24.5 | 23.two | 20.five | 17.8 | 75 | 2400*1470*1840 | 2700 | |
CWD160 PM | one hundred sixty / 215 | 28.8 | 27.eight | 25. | 22.4 | 75 | 2400*1470*1840 | 3000 | |
CWD185 PM | 185 / 250 | 32.five | 31.2 | 28. | 25.eight | 75 | 3150*1980*2150 | 3500 | |
CWD200 PM | 200 / 270 | 36. | 34.3 | 30.5 | 28. | eighty two | 3150*1980*2150 | 4000 | |
CWD250 PM | 250 / 350 | 43. | 41.five | 38.2 | 34.9 | 82 | 3150*1980*2150 | 4500 | |
CWD315 PM | 315 / 400 | fifty one. | 50.2 | forty four.five | 39.five | eighty two | 3150*1980*2150 | 6000 | |
CWD355 PM | 355 / 450 | sixty four. | 61. | fifty six.5 | 49. | eighty four | 3150*1980*2150 | 6500 | |
CWD400 PM | four hundred / 500 | seventy one.two | sixty eight.one | sixty two.8 | fifty two.two | 84 | 3150*1980*2150 | 7200 |
- Unit functionality measured in accordance to ISO 1217, Annex C, Edition 4 (2009)
Reference conditions:
-Relative humidity %
-Complete inlet stress: 1 bar (a) (fourteen.five psi)
-Consumption air temperature: 20°C, 68°F
- Noise level calculated according to ISO 2151:2004, operation at max. working stress and max. velocity tolerance: ±3 dB(A)
- PM-Long lasting CZPT
CZPT TWO-Phase OIL-INJECTED PERMANENT MAGNET Variable Velocity CZPT
Specialized Specifications CWD 7-400 PM
(7.five-400kW / ten-500hp)
Model | Motor Energy kW / hp |
Free of charge Air Delivery m3/min |
Sounds Stage dB(A) |
Dimension L * W * H mm |
Fat Kg |
|||
7barg | 8barg | 10barg | 13barg | |||||
CWD15II-PM | fifteen / twenty | 3. | two.9 | 2.4 | 2.two | 68 | 1480*850*1180 | 780 |
CWD18II-PM | eighteen.5 / 25 | three.6 | 3.five | two.nine | 2.five | 68 | 1480*850*1180 | 800 |
CWD22II-PM | 22 / thirty | 4.two | four.one | three.five | three.2 | 68 | 1480*850*1180 | 820 |
CWD30II-PM | thirty / forty | six.five | 6.4 | 4.nine | 4.two | 68 | 1720*1110*1480 | 1080 |
CWD37II-PM | 37 / 50 | seven.two | seven.1 | six.three | 5.four | sixty eight | 1720*1110*1480 | 1100 |
CWD45II-PM | 45 / 60 | nine.8 | 9.7 | seven.8 | 6.five | 72 | 1720*1110*1480 | 1120 |
CWD55II-PM | fifty five / seventy five | twelve.eight | 12.five | nine.6 | 8.six | 72 | 2100*1350*1720 | 2080 |
CWD75II-PM | 75 / one hundred | 17.5 | 16.5 | 12.5 | eleven.two | seventy two | 2100*1350*1720 | 2100 |
CWD90II-PM | ninety / 125 | 20.eight | 19.8 | 16.9 | 14.three | seventy two | 2460*1700*1900 | 3280 |
CWD110II-PM | one hundred ten / one hundred fifty | 24.five | 23.five | 19.7 | seventeen.six | seventy two | 2460*1700*1900 | 3480 |
CWD132II-PM | 132 / one hundred eighty | thirty. | 28. | 23.5 | 19.8 | 75 | 2900*1800*2571 | 3980 |
CWD160II-PM | 160 / 215 | 34.5 | 33.six | thirty. | 23.8 | seventy five | 2900*1800*2571 | 4280 |
CWD185II-PM | 185 / 250 | 41. | 38.4 | 32.5 | 28.6 | 75 | 3800*1980*2150 | 5450 |
CWD200II-PM | two hundred / 270 | 44.six | 43. | 38.5 | 32.8 | eighty two | 3800*1980*2150 | 5600 |
CWD220II-PM | 220 / three hundred | 48.six | forty seven. | forty one. | 38. | eighty two | 3800*1980*2150 | 6500 |
CWD250II-PM | 250 / 350 | 55. | fifty four. | 46. | 40. | eighty two | 3800*1980*2150 | 6600 |
- Unit performance measured in accordance to ISO 1217, Annex C, Version four (2009)
Reference situations:
-Relative humidity %
-Absolute inlet force: 1 bar (a) (fourteen.five psi)
-Consumption air temperature: 20°C, 68°F
- Sounds stage calculated in accordance to ISO 2151:2004, operation at max. running strain and max. velocity tolerance: ±3 dB(A)
- II-Two Phase, PM-Permanent CZPT