CZPT Oil-Injected Rotary CZPT CZPTs
CWD 7-400 & CWD 7-four hundred PM
Power output: seven-four hundred kW / ten-500 hp
Delivery fee: .8-seventy one.two m3/min / 28-2514 cfm
Pressure variety: seven-13 bar / 100-190 psig
CZPT CZPT – Optimum STHangZhouRD
SIMPLICITY BUT NOT Easy
For 3 generations, consumers from mechanical engineering, market and trade have relied on CZPT know-how when it arrives to plHangZhou, creating and manufacturing compressed air methods. They are completely aware of the reality that CZPT AIR is more than just normal compressed air: utmost security, outstanding efficiency, outstanding top quality, maximized adaptability together with trustworthy services are the ingredients to change CZPT AIR into air to work with – in China, in Asia and in more than 102 nations all around the entire world.
The III era, the basis for economical compressed air creation
The Know-How
A lot more than decades of know-how in producing for the compressed air market. World broad information in different compressed air apps have guided the growth of customer specified stationary screw compressors.
CZPT Development for your Advantage
The edge of CZPT lies in its simplified building. Less factors are used. This implies a sixty% reduction in primary and wearing parts and above 70% less pipes and connections. In turn, this tremendously lowers the chance of leakages, making the technique environmentally friendly. Risk-free immediate generate procedure without V-belt transmission.
The CZPT CZPT CZPT operates in the adhering to way:
Ambient air is drawn through the intake filter and the multifunctional manage program into the screw compressor block. This block is made up of a pair of screw rotors. The primary rotor, driven by an electric motor, requires the CZPTary rotor with it. The air is drawn in by the rotation of each of the interlocking rotors and is continually compressed. For the duration of rotation, coolant is injected into the rotors and types a hydrostatic movie among the major and CZPTary rotors. The perform of the coolant is to seal the rotors, lubricate the bearings and adsorb the compression heat. Just before compressed air leaves the compressor ( at eighty ºC approx.) it is separated from the coolant ahead of currently being cooled in the aftercooler to approx.. 8ºC to 12ºC above the ambient temperature. The coolant then passes to the thermostatic manage block and filter, just before moving into the cooler exactly where it is cooled from approx.. 80ºC down to 50ºC. It is then injected back into the screw compressor block.
Functions:
Immediate push via versatile coupling.
Fully encapsulated CZPT screw compressor block.
Standard electric powered motor CZPT Index IP23 and IP54.
Consumer friendly services accessibility.
Top top quality, washable, oil resistant sound insulation.
All set for operation, prewired and totally enclosed.
With working method selector change CZPT-Off-Constant.
Centrally mounted cooling admirer presented for compressed air and lubricant coolers.
Compact and neat cabinet layout.
Optional CZPT:
Sense of rotation
A number of device handle with computerized base load choice
Full motor defense
Mains isolator switch for wall mounting
CZPT these functions we supply a extensive decision of compressed air equipment in reference to our compressor item variety.
CZPT Recovery Programs CZPT-THERM
Compressed Air CZPTs
Compressed Air Dryers
Condensate Traps
Oil-Drinking water Separators
Compressed Air Receivers
CZPT OIL-INJECTED Permanent MAGNET CZPT
Technical Technical specs CWD 7-four hundred PM
(7.five-400kW / 10-500hp)
Model | Motor Power kW / hp |
Cost-free Air Shipping m3/min |
Sound Degree dB(A) |
Dimension L * W * H mm |
Bodyweight Kg |
|||
7barg | 8barg | 10barg | 13barg | |||||
CWD7 PM | seven.5 / ten | one.3 | one.two | 1. | .eight | sixty six | 760*seven hundred*920 | two hundred |
CWD11 PM | 11 / fifteen | 1.seven | 1.6 | one.4 | 1.two | 68 | 980*750*one thousand | 350 |
CWD15 PM | fifteen / 20 | 2.5 | 2.three | 2.one | 1.9 | sixty eight | 980*750*one thousand | 360 |
CWD18 PM | eighteen.5 / twenty five | three.two | three. | two.seven | 2.4 | sixty eight | 1120*850*1160 | five hundred |
CWD22 PM | 22 / 30 | three.8 | three.6 | 3.2 | two.8 | sixty eight | 1120*850*1160 | 520 |
CWD30 PM | 30 / 40 | five.3 | 5. | 4.five | four. | 68 | 1120*850*1160 | 550 |
CWD37 PM | 37 / fifty | six.8 | six.2 | 5.6 | five. | sixty eight | 1280*1000*1290 | 750 |
CWD45 PM | 45 / sixty | 8. | 7.three | seven. | five.9 | seventy two | 1280*a thousand*1290 | 780 |
CWD55 PM | 55 / seventy five | ten.one | 9.5 | eight.7 | seven.8 | 72 | 1800*1230*1570 | 1600 |
CWD75 PM | 75 / 100 | thirteen.six | twelve.8 | twelve.three | ten.two | 72 | 1800*1230*1570 | 1800 |
CWD90 PM | 90 / a hundred twenty five | 16.2 | 15.five | 14. | 12.five | 72 | 1800*1230*1570 | 1900 |
CWD110 PM | 110 / one hundred fifty | 21.two | 19.eight | seventeen.8 | fifteen.5 | 72 | 2400*1470*1840 | 2500 |
CWD132 PM | 132 / one hundred eighty | 24.five | 23.two | 20.five | 17.8 | seventy five | 2400*1470*1840 | 2700 |
CWD160 PM | one hundred sixty / 215 | 28.eight | 27.eight | 25. | 22.4 | 75 | 2400*1470*1840 | 3000 |
CWD185 PM | 185 / 250 | 32.5 | 31.2 | 28. | twenty five.8 | 75 | 3150*1980*2150 | 3500 |
CWD200 PM | 200 / 270 | 36. | 34.three | thirty.5 | 28. | 82 | 3150*1980*2150 | 4000 |
CWD250 PM | 250 / 350 | forty three. | forty one.5 | 38.2 | 34.nine | 82 | 3150*1980*2150 | 4500 |
CWD315 PM | 315 / 400 | 51. | 50.two | forty four.5 | 39.five | eighty two | 3150*1980*2150 | 6000 |
CWD355 PM | 355 / 450 | sixty four. | sixty one. | fifty six.five | 49. | eighty four | 3150*1980*2150 | 6500 |
CWD400 PM | 400 / five hundred | 71.two | 68.one | 62.eight | 52.2 | eighty four | 3150*1980*2150 | 7200 |
- Unit performance measured in accordance to ISO 1217, Annex C, Version four (2009)
Reference problems:
-Relative humidity %
-Absolute inlet stress: 1 bar (a) (fourteen.5 psi)
-Ingestion air temperature: 20°C, 68°F
- Noise degree calculated according to ISO 2151:2004, procedure at max. working strain and max. speed tolerance: ±3 dB(A)
- PM-Everlasting CZPT