Twin CZPTs CZPT Gshp for CZPT and Heating Chiller
We have these products:
3kw ~ 3000kw/Outlet temperature:7ºC~ -85ºC/
Air cooled,water cooled,screw kind,scroll variety,heat pump chiller, modular chiller.
The Particulars of the chiller:
one.The Temperature Variety:7ºC to -85ºC.
2.CZPT Potential Selection:
1RT to 1000RT
3.52kw to 3520kw
12571Btu to 12571240Btu
3571.2Kal to 3571200Kal
3. The Refrigerant: R22/R407c/R410a/R404a/R134a/R507c.
four. We have many types water chiller and we can also create the chiller
according to your specifications.
One particular Parameter of our h2o chiller:
1 Parameter of our drinking water chiller:
Model | WD- | ||||||||||||||||||||||||
Unit | 188.1WSM3 | 220.1WSM3 | 235.1WSM3 | 260.1WSM3 | 260.1WSM3 | 290.1WSM3 | 335.1WSM3 | 372.1WSM3 | four hundred.1WSM3 | 445.1WSM3 | |||||||||||||||
CZPT potential | Btu | 641456.00 | 750640.00 | 801820.00 | 887120.00 | 955360.00 | 989480.00 | 1143571.00 | 1269264.00 | 1364800.00 | 1518340 | ||||||||||||||
RT | 53.41 | 62.fifty | 66.seventy six | 73.86 | seventy nine.55 | eighty two.39 | 95.seventeen | a hundred and five.sixty eight | 113.64 | 126.forty two | |||||||||||||||
K w | 188.00 | 220.00 | 235.00 | 260.00 | 280.00 | 290.00 | 335.00 | 372.00 | four hundred.00 | 445.00 | |||||||||||||||
×10fourKcal/h | 16.00 | 19.00 | twenty.00 | 22.00 | 24.00 | twenty five.00 | 29.00 | 32.00 | 34.00 | 38.00 | |||||||||||||||
Manage manner | PLC automated control | ||||||||||||||||||||||||
electrical power supply | 380V/3N/50HZ | ||||||||||||||||||||||||
CZPT | Type | five-6 asymmetric semi-hermetic twin screw compressors | |||||||||||||||||||||||
CZPTtup type | Y-△ | ||||||||||||||||||||||||
CZPT regulation | -12.five%-25%-37.5%-50%-62.5%-75%-87.five%-a hundred% | ||||||||||||||||||||||||
Qty | 1 | ||||||||||||||||||||||||
Enter energy | KW | 81.70 | 94.90 | a hundred.20 | 108.50 | 116.80 | a hundred and twenty.60 | 141.70 | 157.20 | 166.90 | 184.00 | ||||||||||||||
Operation Present | A | 142.20 | one hundred sixty five.10 | 174.30 | 188.eighty | 203.twenty | 209.80 | 246.60 | 273.fifty | 290.40 | 320.20 | ||||||||||||||
Condenser | Sort | Large effectiveness copper dry variety shell-and-tube heat exchanger | |||||||||||||||||||||||
Water pipe link | DN100 | DN125 | DN150 | ||||||||||||||||||||||
CZPT Drinking water Flow | m³/h | sixty one.thirty | 71.fifty | seventy six.20 | 83.70 | 90.20 | 93.30 | 108.30 | one hundred twenty.20 | 128.80 | 142.ninety | ||||||||||||||
H2o stress | kpa | 58.00 | fifty eight.00 | 65.00 | 70.00 | 70.00 | seventy one.00 | seventy one.00 | 72.00 | seventy two.00 | seventy two.00 | ||||||||||||||
Evaporator | Type | Horizontal shell-and-tube/Coil sort high effectiveness copper heat exchanger | |||||||||||||||||||||||
Water pipe connection | DN80 | DN100 | DN125 | ||||||||||||||||||||||
Freezing drinking water Circulation | m³/h | forty.00 | forty seven.50 | 50.00 | fifty five.00 | 60.00 | 62.50 | seventy two.fifty | 80.00 | eighty five.00 | 95.00 | ||||||||||||||
Water pressure | kpa | 58.00 | fifty eight.00 | sixty seven.00 | 72.00 | 72.00 | 72.00 | seventy two.00 | seventy two.00 | seventy two.00 | seventy three.00 | ||||||||||||||
Refrigerant | Type | R22 | |||||||||||||||||||||||
kilogram | kg | 64.00 | 75.00 | 80.00 | 89.00 | 96.00 | ninety nine.00 | 114.00 | 127.00 | 136.00 | 152.00 | ||||||||||||||
Security protection | Large and reduced strain protection high and minimal stress protection over temperature protection overload protection ,over temperature protection, phase sequence security, etc | ||||||||||||||||||||||||
Dimensions (L*W*H) | Length | mm | 3225 | 3225 | 3225 | 3505 | 3605 | 3605 | 3720 | 3720 | 3720 | 3930 | |||||||||||||
Width | mm | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | 1100 | ||||||||||||||
High | mm | 1830 | 1830 | 1880 | 1880 | 1950 | 1980 | 1880 | 1950 | 1970 | 2571 | ||||||||||||||
Internet Fat | kg | 1970 | 2190 | 2440 | 2480 | 2650 | 2950 | 3080 | 3300 | 3470 | 3620 | ||||||||||||||
Operating fat | kg | 2190 | 3380 | 2570 | 2740 | 2950 | 3210 | 3330 | 3570 | 3810 | 3930 |
Note:
one.Freezing h2o inlet temperature -10ºC, freezing h2o outlet temperature -15 ºC cooling drinking water inlet temperature of 30 ºC, cooling water outlet temperature of 35 ºC
two.Temperature circumstances: Freezing drinking water outlet temperature range five ºC-fifteen ºC, cooling water inlet temperature range 19 -33 ºC
three.Protected running assortment : Freezing h2o inlet temperature 9ºC-20ºC
4.The utilizing compressor is shut turbine imported from CZPTe and the CZPT States , superior efficiency, powerful ability of anti-effusion
five.Nominal operating circumstances in the evaporator and condenser drinking water facet fouling issue of .018m² ºC / kw, condenser h2o aspect fouling element of .044 m² ºC / kw
six. Water aspect of the evaporator and condenser, made to withstand a stress of one.0MPa
7. The actual head of Host is that the pump head minus head losses inside the host
eight.In addition to the specifications and needs, we can supply non-CZPT items in accordance to consumer demands.
Firm profile:
Winday CZPT is a professional R & D manufacturing and revenue of industrial refrigeration equipment
and refrigeration system layout, installation service company.
On behalf of product good quality performance “efficient stability, progress energy efficiency.”
CZPT manufacturing process to attain excellence, strict management, strict examination
CZPT program design to achieve repeated investigation, experiment, scrutiny, feasibility
research and other processes,and strive to supply consumers with an optimized cooling program integration answers and equipment.
Get in touch with Way: