3 2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell

3 2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell

3/2 NAH Pumping slurry from conditioning tank to flotation cell 

CZPT® NAH series centrifugal slurry pumps and spare parts can completely interchange.These pumps are of large-obligation building,developed for steady pumping of very abrasive and corrosive slurries.They feature a wide choice of replaceable abrasion resistant steel or moulded elastomer casting liners and Impellers,which are all interchangeable in a common casting assembly.

1.Double Liner Centrifugal Pump
two.CZPT or substantial chrome alloy impeller
3.Big flow in medium head
4.CZPT variety:ZV CV DC CR CL
five.Types of 4 seal to prevent leakage:Packing Seal # Expeller Seal # CZPT Seal # Dyna Seal

Standard Purposes—-
CZPTs Flotation Processing
CZPTtric Manufacturing unit Coal Preparing
Coal Washing
CZPT Medium Processing
Effluent Dealing with
Salt and Sugar CZPTSand And Gravel Handling

CZPT Drawing

  LINERS IMPELLERS CASING Foundation EXPELLER EXPELLER RING SHAFT SLEEVE SEALS
Normal Chrome Alloy
CZPT CZPT
Chrome Alloy
CZPT CZPT
SG Iron SG Iron Chrome Alloy
or
SG Iron
Chrome Alloy
or
SG Iron
SG Iron CZPT
and
Nitrile
Alternatives Ferralium
Hastelloy C
316 SS
W151
CZPTurethane
Neoprene
Butyl
Viton
Nitrile
EPDM
Hypalon
Ferralium
Hastelloy C
316 SS
W151
CZPTurethane
Neoprene
Butyl
Nitrile
Hypalon
SG Iron
A variety of grades
MS
Fabricated
Solid Iron
NI Resist
Ferralium
Hastelloy C
CZPTurethane
316 SS
W151
NI Resist
Ferralium
Hastelloy C
316 SS
CZPT
W151
CZPTurethane
Neoprene
Butyl
Nitrile
EN56C
Ferralium
Hastelloy C
CZPT
316 SS
304 SS
Ceramic
Stellite
Chrome Oxide
Nordel
Neoprene
Viton

Pump Efficiency Parameters

CZPT® NAH Metal LINER PUMP Operate PARAMETER

Sort Allowable Mating Max.Electrical power(Kw) Very clear H2o Functionality Impeller
Ability/Q m³/hr Head/m Velocity/rpm Max Effectiveness/% NPSH/m Nos of Vane Impeller Diameter/mm
1.5/1NAH 15 twelve.6–28.eight 6–sixty eight 1200–3800 forty two–four 5 152
two/one.5NAH fifteen 32.four–72 6–fifty eight 1200–3200 forty five 3.5–8 five 184
three/2NAH 30 39.6–86.4 12–sixty four 1300–2700 fifty five four–6 five 214
4/3NAH thirty 86.4–198 nine–52 a thousand–2200 71 four–6 five 245
6/4NAH sixty 162–360 twelve–56 800–1550 65 five–8 5 365
8/6NAH three hundred 360–828 10–sixty one 500–1140 seventy two 2–nine 5 510
ten/8NAH 560 612–1368 eleven–61 four hundred–850 seventy one 4–10 five 686
12/10NAH 560 936–1980 seven–sixty eight 300–800 82 6 five 762
fourteen/12NAH 560 1260–2772 13–sixty three 300–600 seventy seven 3–10 five 965
16/14NAH 1200 1368–3060 eleven–sixty three 250–550 79 4–ten 5 1067
20/18NAH 1200 2520–5400 thirteen–fifty seven 200–400 eighty five five–ten 5 1370

3/2 C- NAH  Main Elements Checklist
 

3/2C-NAH Shaft Sleeve C075
Base  C003M
Lantern Ring C063
Lantern Restrictor C118
Packing Seal C067
Frame Plate  C2032
Cover Plate C2013
Impeller  C2147
Volute C2110NA
Body Plate Liner Insert  C2041
Shaft Spacer C117
Stuffing Box C078
Expeller  C571
Expeller Ring  C571
Suction Gasket  C2060
Discharge Gasket C2132XLP
Volute Liner Seal C2125
Seal Ring C122
Labyrinth Ring C108
Oil Cup Base D138
Bearing Housing C004M
Stop Go over C571
Grease Retainer C046
Labyrinth Sleeve C062
Shaft  C073M
Bearing Assembly C005M

Solution Overview:

For the AH pump kinds,we can offer as beneath,

one.5/1B-AH(R)  2/1.5B-AH(R) three/2C-AH(R) four/3C-AH(R) 6/4D-AH(R) six/4E-AH(R) eight/6E-AH(R)
8/6R-AH(R)  10/8F-AH(R)  10/8ST-AH(R)  12/10ST-AH(R)  12/10FF-AH(R)  14/12G-AH(R)
fourteen/12ST-AH(R)  16/14TU-AH(R)  20/18TU-AH(R)

Our Workshop Show:

NAIPU PUMP is a whole processing organization, CZPTt from Modeling Workshop,Casting Workshop,Heat therapy Workshop,Machining Workshop ,Assembly Workshop and Pump Screening Workshop are all by us. So we are modernization and integrated company to satisfy the requirement of the altering needs of market place.

We established various verify points together the total production line,which through Raw Material,Charging Content,Floor and Warmth Remedy examining,Content Examination,Spare Screening and Pump Tests and so on.

Feasible Faults and Settlements 
 

        Faults      Reason        Settlement
one.Pump fails to discharge any h2o,The hand of stress gauge conquer violently  1.Suction pipe do not have enough water.
2.Suction pipe blocked or the valve is locked.
1. Inject sufficient water
two.unlock the inlet valve,distinct the blocks
3.Exclude the air leakage 
two.The pump cannot discharge h2o,the hand of vacuum meter beat seriously.  1.The inlet valve is unlocked or silted up.
2.The resistance of suction pipe is also big or silted up.
3.The top of suction is also substantial. 
one.Unlock the valve or desilting 
2.boost the design and style of  suction pipe or desilt 
3.Decrease the height of the installation.
3.The pump cannot discharge drinking water,force gauge demonstrates heavy pressure. one.The resistance of the discharge pipe is too large.
2.The impeller blocked
3.The pace is gradual.
one.Check out and change the outlet pipe.
two.Obvious the impeller
three. Increase the pace.
four.The pump does not rotate  The volute is silted up by the blocks.  Distinct the blocks
5.The potential is not enough  one.The blocks of the impeller or the inlet or outlet pipe.
2.The abrasion of the impeller is seriously.
3.The velocity is minimal to normal 
four.Pump is put in unreasonably or the leakage of the inlet pipe.
five.The transporting top is way too high,the reduction of the resistance of the within pipe are way too huge.
six.The inlet valve not open up enough or blocked
7.The packing seal leaks
1.Distinct the impeller or pipe.
two.Adjust the impeller

3.Modify the speed
four.Put in once again or quit leaking.

 

  1. Lessen the peak of the transport or lessen the resistance.
  2. Unlock the inlet valve

 

  1. Compress the packing tightly
6.The motor of the pump is overloaded  one.The head of the pump exceeds the head of the functioning issue.
2.Not contemplate the slurry density when selecting the pump.
three.The packing push tightly
one.Flip down the outlet valve,cut the impeller or reduced the speed.
2.Pick the motor yet again.
3.Alter the the screw of the  packing gland 
seven.Abnormal sound in the pump, and no water out 1.The resistance of the inlet pipe is as well massive.
two.The peak of the suction is as well large.
3.Cavitation occurred 

  1. there is air in the inlet
  2. The temperature of the liquid is way too large
  1. Obvious the suction pipe and sluice valve.
  2. Reduce the peak of the suction 
  3. Change the drinking water valve and let the pump run in the defined restrictions.
  4. Block the leakage.
  5. Reducing the liquid temperature.
8.pump vibrates one.pump cavitate 
2.The block of the impeller single vane 
3.The no concentricity  between the pump shaft and motor shaft
4.CZPTeners or foundation loose
1.Change the water valve ,reduced the top of the set up,reduce the resistance of the inlet.
2.Obvious the impeller
3.Alignment once more
four.CZPTen the screw,and fortify the basis.
nine.Bearing is overheat  1.lock the cooling water
2.lubrication is not good.
three.the lubrication oil is not obvious
4.the wrong route of the thrust bearing.
five.there is some thing improper with the bearing.
  1. Open up the cooling h2o
  2. Change the oil quantity 
  3. Clear the shaft,adjust oil
  4. According to the inlet strain,modify the route of the thrust bearing.
  5. Adjust the bearing 
10.Packing quick life  The material of packing is not good  Change the packing 
11.pump leak oil 1.Substantial oil stage
two.The rubber parts invalid  
3.Assembly problem
one.Lower the oil level
two.Adjust rubber spares
three.Adjust the assembly
 
twelve Pump head leaking  one.The rubber elements not press properly Assembly again or push tightly 

Programs

Large Sand and Gravel Principal CZPT Slurry Services Pulp And Paper Operations Ash Handling Transportation Transportation Foodstuff Explosive Sludge In Metallic River And Pond Dredging Removing Lower NPSHA Purposes Procedure Steel Blending Speak to Us 

Make contact with Particular person: Karen Tan  

 

 

 

3 2 Nah Pumping Slurry From Conditioning Tank to Flotation Cell