Cooling System for Brewery; Glycol Tank; Chiller; Cooling Unit

Cooling System for Brewery Glycol Tank Chiller Cooling Unit

Merchandise Description

Features
The master module can work independently or together with up to 16 slave modules.

Units with V type heat exchanger: panels, frame and base are manufactured from galvanized metal protected with polyester powder portray to make sure whole resistance to atmospheric agents.

three-phase scroll sort compressor, with built-in thermal overload lower-out and crankcase heater, mounted on rubber vibration dampers.

External rotor kind axial fans, geared up with three phase direct push motors, lower noise 8 poles, safety level IP54, offered with a protective outlet grille.

Evaporator built with large efficiency Shell and tube type heat exchanger, factory insulated with versatile shut mobile substance. 

Condenser developed with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.

Refrigerant circuit comprehensive with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve, high & low pressure switch. The warmth pump device is finished also with 4-way valve, liquid receiver and one way valve.

CZPT circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from equally sides of the models.

CZPTtric panel consist of: compressor contactor, fan motor contactor, compressor defense breaker, fan security breaker, phase sequence relay and microprocessor with perform display (screen only for grasp/packaged device)

CZPT procedure dramatically minimizing servicing price thanks to dependable microprocessor method. 

OPTIONAL 

Paddle flow switch
CZPTc filter for hydraulic circuit
H2o pump
CZPT antivibration mounting.
Heat recovery capabilities

Complex Information

Model  LSQW(R)F   60 100 130 200 260
CZPT potential* kW 65 97.5 130 195 260
CZPT electrical power enter kW 20.eight 31.four 42.one 63.6 84.two
Heating capacity** kW 68 102 136 204 272
Heating electrical power enter kW twenty.two 30.six 41 61.2 82
Max Enter Power kW 24 35.seven 47.seven seventy one.four ninety five.four
Max Input current A 50 seventy four ninety seven 148 194
CZPT Operating Recent A 46 68 89 136 178
CZPTt-Up Existing A 167 187 206 374 412
CZPT
Electricity supply / 380/three/fifty
Brand name/Type / CZPT/Scroll
Refrigerant / R410a
Qty/refrigerant circuit Nr. 2 three 4 six eight
CZPT power input* kW 2*9.four three*9.63 four*nine.77 6*nine.sixty three eight*nine.seventy seven
Heating electricity enter** kW two*9.one three*nine.36 4*nine.five 6*9.36 8*nine.5
CZPT adjustment % -25-50-seventy five-100 
Axial fan
Amount Nr. two 2 2 four four
Electricity enter kW 2 two.five three five 6
Airflow mthree/h 24000 36000 48000 72000 96000
Evaporator
Variety / Shell and tube heat exchanger
  Water flow when cooling m3/h 11.two sixteen.eight 22.4 33.six 44.8
  Water flow when heating m3/h eleven.seven 17.6 23.four 35.1 forty six.eight
  Water side pressure drop *** kPa forty six fifty two fifty five 52 fifty five
 Water connection measurement DN fifty 50
 
sixty five 2×50 2×65
Noise level***   dB(A) 70 72 72 74 75
Dimensions  
V type coil Duration mm 2000 2207 2207 2207 2207
Width mm 1060 1300 1300 2207 2207
Top mm 1957 2076 2076 2096 2096
Internet fat   kg 620 1060 1120 2160 2280
Functioning fat   kg 635 1090 1155 2220 2350

*Ambient temperature 35ºC evaporator water out -5 ºC
*** In the nominal h2o flow condition the force drop is between this range.
**** Audio stress measured at a length of 1 m and a top of one.five m above the ground in a dear field.
 

Cooling System for Brewery Glycol Tank Chiller Cooling Unit