Shenglin T3 Marine Rooftop AC Heat Pump for Ship

Shenglin T3 Marine Rooftop AC Heat Pump for Ship

CZPT CZPT T3 50Ton Rooftop air conditioner utilized in industrial
For additional info you should get in touch with me:
Meiling
 
 

CZPT Optional

  1. Economizer with fresh, return air dampers and new air hood.
  2. Cost-free cooling perform for minimal ambient temperature.
  3. Minimal ambient control gadget for procedure of out of doors units at ambient temperatures from less than 20°C down to -10°C
  4. BMS gadgets.
  5. T3 (Tropical climate).
  6. Condenser coil guard.
  7. Roof curb.
  8. Metallic / aluminum filter.
  9. Air pressure swap for indoor fan.
  10. Higher static condenser admirer choice with sealed + drain.condensing part.
  11. Optional drinking water heating coil.
  12. Metal or plastic mesh on condenser coil.
  13. Optional source / return air configurations.
  14. Upgraded evaporator fan motor drives.
  15. G4 filter, plate and bag filter

CZPT knowledge:

Model SRF120ZA SRF140ZA SRF150ZA SRF180ZA SRF210ZA SRF300ZA
  SF120ZA SF140ZA SF150ZA SF180ZA SF210ZA SF300ZA
Nominal cooling capacity kW 120 a hundred and forty 149 180 210 298
Nominal heating capability kW 128.3 one hundred fifty 159.2 192.five 226 318
CZPT regulation
 
% ,twenty five,fifty,75,a hundred ,50,one hundred ,16.6,33.three,50,66.4,83,a hundred ,twenty five,fifty,seventy five,a hundred
Power supply 380V / 3Ph / 50HZA
CZPT input potential kW 45.1 55.7 55.1 sixty nine.nine eighty three 106.7
Heating enter capability kW forty one.seven fifty one.8 51.five 64.8 seventy seven 100
CZPTt existing A 218 252 323 232 301 415
CZPT managing recent A eighty two.four 101.four 100.two one hundred thirty.9 151 192.3
Heating working current A seventy seven.four 95.7 95.1 123.five 142.three 184.3
Throttling approach Thermal expansion valve
CZPT technique four 4 two six 6 four
Refrigerant R410A
CZPT Sort Hermetic scroll compressor  380V / 3Ph / 50HZA
  Qty 4 four two 6 6 four
Condensation side
Condenser Kind Copper pipe copper fin
Enthusiast Qty two 2 two four 4 4
  CZPT type Direct generate
  Motor electricity kW 2X1.5 2×2.two 2×2.2 4X1.1 4X1.5 4×2.two
  Air quantity m/h 42000 54000 54000 66000 84000 108000
Evaporation side  
Evaporator Kind Copper pipe copper fin
  Qty 1 1 one one one one
  Motor energy kW 7.5 eleven 11 15 fifteen eighteen.5
  Air quantity m/h 21000 25000 26000 32000 38000 54000
  CZPT kind Pulley
Static strain(Pa) four hundred four hundred   500 500 500
CZPT Aluminum filter G3
Sounds dB(A) 75 seventy nine seventy nine 80 80 82
Refrigerant filling volume(kg) 4×7.five 4×8.five 2×17 6×7.five 6×8.five 4×14
Overall proportions Size(mm) mm 3626 3626 3626 4690 4690 5660
  Width(mm) mm 2200 2200 2200 2330 2330 2330
  Height(mm) mm 2047 2047 2047 2055 2427 2055
Weight kg 1710 1820 1850 2180 2430 2860

one. Nominal cooling potential is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and out of doors DB/WB temperature is 35ºC/24ºC condition
2. Nominal heating capacity is underneath nominal air quantity, indoor DB/WB temperature is 20ºC/15ºC and out of doors DB/WB temperature is 7ºC/6ºC situation

CZPT Attributes
Construction

Panels and body are created from galvanized metal safeguarded with polyester powder painting to guarantee overall resistance to atmospheric agents.
Immediate expansion coils with condensate drain tray.
Hermetic compressor
High efficiency scroll compressor for the complete assortment, with constructed-in thermal overload reduce-out and crankcase heater,mounted on rubber vibration dampers
Ripple type acoustic insulation for compressor area, and thermal insulation for coil and supporter area, minimal sounds
Centrifugal supporter
CZPT curve centrifugal fans for air treatment method segment and axial supporters for condensation area. Entrance, facet and underside air discharge of the treatment unit. Higher external strain, long air source length
CZPTtric panel
CZPTtric panel consists of breakers and contactors for compressors and supporter motors, stage sequence relay and other needed defense products for the major components.
Easy operation line controller
CZPT/Heating/Vehicle. Error indication. Timing on/off.

Manufacturing unit Display

 
 
 

Shenglin T3 Marine Rooftop AC Heat Pump for Ship