CZPT CZPT T3 50Ton Rooftop air conditioner utilized in industrial
For additional info you should get in touch with me:
Meiling
CZPT Optional
- Economizer with fresh, return air dampers and new air hood.
- Cost-free cooling perform for minimal ambient temperature.
- Minimal ambient control gadget for procedure of out of doors units at ambient temperatures from less than 20°C down to -10°C
- BMS gadgets.
- T3 (Tropical climate).
- Condenser coil guard.
- Roof curb.
- Metallic / aluminum filter.
- Air pressure swap for indoor fan.
- Higher static condenser admirer choice with sealed + drain.condensing part.
- Optional drinking water heating coil.
- Metal or plastic mesh on condenser coil.
- Optional source / return air configurations.
- Upgraded evaporator fan motor drives.
- G4 filter, plate and bag filter
CZPT knowledge:
Model | SRF120ZA | SRF140ZA | SRF150ZA | SRF180ZA | SRF210ZA | SRF300ZA | |||
SF120ZA | SF140ZA | SF150ZA | SF180ZA | SF210ZA | SF300ZA | ||||
Nominal cooling capacity | kW | 120 | a hundred and forty | 149 | 180 | 210 | 298 | ||
Nominal heating capability | kW | 128.3 | one hundred fifty | 159.2 | 192.five | 226 | 318 | ||
CZPT regulation |
% | ,twenty five,fifty,75,a hundred | ,50,one hundred | ,16.6,33.three,50,66.4,83,a hundred | ,twenty five,fifty,seventy five,a hundred | ||||
Power supply | 380V / 3Ph / 50HZA | ||||||||
CZPT input potential | kW | 45.1 | 55.7 | 55.1 | sixty nine.nine | eighty three | 106.7 | ||
Heating enter capability | kW | forty one.seven | fifty one.8 | 51.five | 64.8 | seventy seven | 100 | ||
CZPTt existing | A | 218 | 252 | 323 | 232 | 301 | 415 | ||
CZPT managing recent | A | eighty two.four | 101.four | 100.two | one hundred thirty.9 | 151 | 192.3 | ||
Heating working current | A | seventy seven.four | 95.7 | 95.1 | 123.five | 142.three | 184.3 | ||
Throttling approach | Thermal expansion valve | ||||||||
CZPT technique | four | 4 | two | six | 6 | four | |||
Refrigerant | R410A | ||||||||
CZPT | Sort | Hermetic scroll compressor 380V / 3Ph / 50HZA | |||||||
Qty | 4 | four | two | 6 | 6 | four | |||
Condensation side | |||||||||
Condenser | Kind | Copper pipe copper fin | |||||||
Enthusiast | Qty | two | 2 | two | four | 4 | 4 | ||
CZPT type | Direct generate | ||||||||
Motor electricity | kW | 2X1.5 | 2×2.two | 2×2.2 | 4X1.1 | 4X1.5 | 4×2.two | ||
Air quantity | m3 /h | 42000 | 54000 | 54000 | 66000 | 84000 | 108000 | ||
Evaporation side | |||||||||
Evaporator | Kind | Copper pipe copper fin | |||||||
Qty | 1 | 1 | one | one | one | one | |||
Motor energy | kW | 7.5 | eleven | 11 | 15 | fifteen | eighteen.5 | ||
Air quantity | m3 /h | 21000 | 25000 | 26000 | 32000 | 38000 | 54000 | ||
CZPT kind | Pulley | ||||||||
Static strain(Pa) | four hundred | four hundred | 500 | 500 | 500 | ||||
CZPT | Aluminum filter G3 | ||||||||
Sounds dB(A) | 75 | seventy nine | seventy nine | 80 | 80 | 82 | |||
Refrigerant filling volume(kg) | 4×7.five | 4×8.five | 2×17 | 6×7.five | 6×8.five | 4×14 | |||
Overall proportions | Size(mm) | mm | 3626 | 3626 | 3626 | 4690 | 4690 | 5660 | |
Width(mm) | mm | 2200 | 2200 | 2200 | 2330 | 2330 | 2330 | ||
Height(mm) | mm | 2047 | 2047 | 2047 | 2055 | 2427 | 2055 | ||
Weight | kg | 1710 | 1820 | 1850 | 2180 | 2430 | 2860 |
one. Nominal cooling potential is under nominal air volume, indoor DB/WB temperature is 27ºC/19ºC and out of doors DB/WB temperature is 35ºC/24ºC condition
2. Nominal heating capacity is underneath nominal air quantity, indoor DB/WB temperature is 20ºC/15ºC and out of doors DB/WB temperature is 7ºC/6ºC situation
CZPT Attributes
Construction
Panels and body are created from galvanized metal safeguarded with polyester powder painting to guarantee overall resistance to atmospheric agents.
Immediate expansion coils with condensate drain tray.
Hermetic compressor
High efficiency scroll compressor for the complete assortment, with constructed-in thermal overload reduce-out and crankcase heater,mounted on rubber vibration dampers
Ripple type acoustic insulation for compressor area, and thermal insulation for coil and supporter area, minimal sounds
Centrifugal supporter
CZPT curve centrifugal fans for air treatment method segment and axial supporters for condensation area. Entrance, facet and underside air discharge of the treatment unit. Higher external strain, long air source length
CZPTtric panel
CZPTtric panel consists of breakers and contactors for compressors and supporter motors, stage sequence relay and other needed defense products for the major components.
Easy operation line controller
CZPT/Heating/Vehicle. Error indication. Timing on/off.
Manufacturing unit Display