Jecicool brand Water-cooling industrial chiller making use of innovative production engineering, excellent good quality, compact framework, beautiful physical appearance. The goods can be extensively used in plastics, electroplating, digital manufacturing, pharmaceutical chemicals, meals processing, laser, ultrasonic awesome, printing and other industries, can precisely manage the demand from customers for modern industrial mechanized generation of temperature, therefore drastically strengthening the creation effectiveness and merchandise quality.
Primary Functions
one. Using CZPT/ Darkin from Japan, or CZPT from the CZPT States and other model compressors, reduced sounds and electrical power saving, A lot more tough
2. Undertake fin and tube condenser, cooling result is great and steady overall performance
3. Evaporator stainless steel water tank, developed-in computerized water unit
four. Undertake imported pumps, stainless metal pump for buyers to decide on from, to avert CZPTary air pollution
5. Microcomputer digital temperature controller, integrated procedure, simple and functional, substantial management precision
6. Utilizing box framework, CNC punch push precision machining, electrostatic energy paint, stylish appearance, geared up with wheel so that effortless to go
7. Chiller Device equipped with reverse phase deficiency defense, motor overload defense, high and reduced voltage protection, temperature defense and other security protection device, produced the method a lot more stable and safe. Little dimensions, light bodyweight, and compact construction
CZPT Parameters:
Parameters | Design | KDE-03W | KDE-05W | KDE-06W | KDE-08W | KDE-10W | |
Nominal CZPT Potential | Kw/50Hz | ten.two | seventeen.2 | 20.three | 27.six | 33.8 | |
Kw/60Hz | 13.26 | 22.36 | 26.39 | 35.88 | forty three.94 | ||
USRT/50Hz | 2.9 | four.9 | 5.eight | 7.8 | 9.6 | ||
USRT/60Hz | three.eight | six.4 | seven.five | ten.2 | 12.5 | ||
Kcal/h/50Hz | 8772 | 1479.2 | 17458 | 23736 | 29068 | ||
Kcal/h/60Hz | 11403.six | 19229.six | 22695.4 | 3571.eight | 37788.4 | ||
Enter Power | KW | two.7 | four.6 | 5.3 | seven | 8.six | |
Max Running Existing | A | 6.seven | ten.five | 12.six | sixteen.5 | 20.four | |
Energy | 3PH 380V 50Hz(200V/220V/415V/460V50Hz/60Hz) | ||||||
Refrigerant | Kind | R22 (R134a/R407c) | |||||
Management Method | Capillary | External-balanced Thermostatic Enlargement Valve | |||||
CZPT | Sort | Airtight Scroll Tpye | |||||
Electricity | KW | 2.25 | 3.75 | four.5 | 6 | 7.5 | |
Condenser | Sort | Shell and Tube | |||||
CZPT H2o Stream | m³/h 50Hz | two.two | 3.six | 4.four | 5.eight | seven.1 | |
m³/h 60Hz | 2.eight | four.8 | 5.6 | 7.7 | 9.four | ||
Inlet/Outlet Pipe Dia. | Inch | one-one/two” | one-one/two” | 1-one/two” | 1-1/two” | one-one/two” | |
Evaporator | Sort | Shell and Tube | |||||
Tank Quantity | L | 60 | 70 | 70 | 150 | a hundred and eighty | |
Chilled Drinking water Movement | m³/h 50Hz | one.8 | three | three.five | four.8 | 5.eight | |
m³/h 60Hz | 2.three | three.9 | four.nine | six.two | seven.six | ||
Inlet/Outlet Pipe Dia. | Inch | 1″ | 1″ | 1″ | 1-1/2″ | one-1/2″ | |
H2o Pump | Electricity | KW | .37 | .seventy five | .seventy five | .seventy five | .seventy five |
Carry | M | twenty | 20 | twenty | twenty | twenty | |
Protective Device | CZPT more than heating security, over recent safety, Substantial/reduced voltage security, above heating safety, circulation security, section safety, Exhausting overheat defense, anti-freezing security | ||||||
Dimension | Size | mm | 850 | 900 | 920 | 1100 | 1250 |
Width | mm | five hundred | five hundred | five hundred | 680 | 600 | |
Height | mm | 880 | 980 | a thousand | 1300 | 1300 | |
Fat | KG | 130 | one hundred sixty | 170 | three hundred | 450 | |
Be aware | 1. The over red font parameters for special voltage product want to particular purchase CZPT capacity of R407C unit will be five% reduce than R22 unit | ||||||
two. Nominal cooling capacity calculated according to: inlet/outlet chilled fluid temperature: 17ºC/12ºC inlet/outlet cooling drinking water temperature: 30ºC/35ºC | |||||||
3. Operating situation: The temperature selection of chilled fluid is from 5ºC to 35ºC temperature difference among inlet and outlet chilled fluid is from 3ºC to 8ºC. | |||||||
4. The temperature selection of cooling drinking water is from 18ºC to 37ºC temperature variation among inlet and outlet cooling water is from three.5ºC to 10ºC. | |||||||
five. The energy distribution and wiring of the set up shall be based on the nameplate or set up instructions of the unit. We reserve the rihgt to modify the earlier mentioned details whithout prior recognize |
Work Basic principle
Applications
JECICOOL industrial chillers are the ideal resolution for any application, in distinct for the plastic subject, such as : injection molding, extrusion(sheet & profile), blow molding, thermoforming, PET, plastic film, and other industrial field : electroplating (surface area treatment), medication, chemical, hydraulic method, leaser, shoe-generating, digital, print, and many others.
Package & CZPT
Use CZPT export plywood circumstance with forklift truck toes, straightforward to load and unload
12-fifteen times to finish the generation following receiving the deposit
CZPT by LCL or FCL
Soon after-sales service:
A. twelve months high quality guarantee considering that the day of shipping and delivery.
B. All extra components for the machine can be purchased with agent value from COOLDERE.
C. 24 hours functioning cellphone phone: 13829879662, E-mail/ Skype/CZPT manager on the internet to assistance.
D. Expert technological staff and revenue individual give you concerning troubleshooting techniques by way of Net and Mobile phone any time when essential.
E. Totally free and Skilled Education at our Factory under the comfortable condition.
Needed data to Quote
COOLDERE business have one particular specific engineer crew for design, they can make the particular resolution in accordance to your doing work need, such as customise cooling capacity, particular content for ship use, seawater, corrosive, meals sector, juice and wine procedure and and so on. Just explain to us:
A. What is your water composition? or sector
B. What is your temperature selection?
C. What’s your chilled drinking water flow want?
D. What is actually the functioning ambient?
E. What voltage do you want?
one. CZPTing Refrigerants: R22, R407, R134a can be equipped on request
2. Particular voltages: 115V 220V~240V 50 Hz or 60Hz (Single and A few Section) are offered then we can decide on the right chiller for you.