Welcome to pay a visit to our manufacturing unit in ZheJiang
As an industrial h2o chiller, this h2o cooled water chiller has the adhering to functions: Chiller, water chiller, h2o cooled chiller
one. CZPT potential: 9.8kw~123kw
2. Normal problems: Chilled water inlet temperature is twelve levels, outlet temperature is seven degrees. Ambient temperature 35 levels.
3. Running variety: Chilled water temperature nine~20 degrees.
4. Input electricity: 3P-380V-50Hz, Allowable fluctuate voltage: ± 10%, allowable voltage distinction in stage: ± two%.
five. Measuring sounds place: 2m forward and 1.5m large in entrance of chiller with regular measurement on four dimensions.
six. Take orders for particular demands.
7. Scroll hermetic compressor worldwide brand-cost-free maintenance.
eight. CZPTtrical elements and refrigeration elements are employed from planet-renowned brand.
nine. CZPT and sturdy layout, with stainless metal h2o tank and high-raise pumps.
10. Vast range of variable chilled water temperature to satisfy the industrial demands throughout total calendar year.
eleven. Developed as an impartial refrigeration circuit, each compressor corresponding to one refrigeration circuit.
12. CZPTly select to use environmentally R407C or R134A refrigerant.
H2o CHILLER, CHILLER, H2o COOLED CHILLER
Item Sort | DLP- | |||||||||||
03WSZ | 05WSZ | 08WSZ | 10WSZ | 12WSZ | 15WSZ | 20WSZ | 20WDZ | 25WDZ | 30WDZ | 40WDZ | ||
Refrigerant capability | kW | nine.eight | 15.nine | 28.six | 31.seven | 36.3 | forty six.0 | sixty one.five | sixty three.4 | seventy two.6 | 91.0 | 123.0 |
103kcal/hr | 8.4 | thirteen.seven | 24.six | 27.two | 31.two | 39.5 | 52.8 | fifty four.five | sixty two.4 | 78.two | one zero five.7 | |
RT | 2.8 | 4.5 | eight.1 | 9.0 | ten.3 | 13.1 | seventeen.5 | 18.0 | twenty.6 | twenty five.9 | 35.0 | |
CZPT | Quantity (SET ) | 1 | one | one | 1 | one | one | 1 | 2 | 2 | 2 | 2 |
CZPT input energy(kW) | 2.one | 3.five | five.seven | six.4 | 7.3 | 10.two | thirteen.eight | twelve.eight | fourteen.6 | twenty.three | 27.7 | |
Operating current (A) | three.9 | 7.0 | ten.five | 11.seven | 15.5 | 20.0 | 21.1 | 23.four | 31.0 | forty.one | 42.2 | |
Input electrical power | kW | 2.five | 4.1 | 6.four | seven.2 | 8.8 | 11.7 | fifteen.3 | fourteen.three | 16.1 | 22.five | 29.9 |
Operating present | A | 4.7 | eight.2 | twelve.one | 13.4 | seventeen | 23.3 | 28.7 | 26.7 | 30.seven | forty four.nine | fifty five.six |
Condenser | Sort | Pipe high efficiency heat exchanger | ||||||||||
CZPT water flow (L/min) | 34 | 55 | 98 | 109 | 125 | 161 | 215 | 218 | 249 | 318 | 431 | |
Interface dimension | twenty five | twenty five | forty | 40 | forty | fifty | 50 | 50 | 65 | sixty five | 65 | |
Evaporator | Type | Pipe dry high efficiency heat exchanger | ||||||||||
Chilled water flow (L/min) | 28 | 46 | 82 | 91 | 104 | 131 | 176 | 182 | 208 | 261 | 353 | |
Interface measurement | twenty five | 25 | forty | 40 | 40 | 50 | 50 | fifty | sixty five | sixty five | sixty five | |
Chilled water pump | Variety | High efficiency, low noise centrifugal water pump | ||||||||||
Input power (kW) | .37 | .fifty five | .seventy five | .75 | 1.five | 1.5 | 1.five | one.5 | one.five | two.two | two.two | |
Head (mH20) | sixteen | 21 | 22 | 19 | 17 | 25 | 24 | 24 | 23 | 22 | 21 | |
Safety products | High & low voltage defense, current overload defense, antifreezing protection, electronical delay security | |||||||||||
Nominal tank volume | L | 85 | ninety | 190 | one hundred ninety | 190 | 210 | 250 | 250 | 250 | 360 | 400 |
Overall size | Length (mm) | 1200 | 1300 | 1350 | 1350 | 1350 | 1600 | 1900 | 1900 | 1900 | 2150 | 2300 |
Width (mm) | 750 | 750 | 850 | 850 | 850 | 900 | 900 | 900 | a thousand | 1000 | 1300 | |
Height (mm) | 900 | 1100 | 1200 | 1200 | 1200 | 1200 | 1200 | 1200 | 1100 | 1200 | 1350 | |
CZPT weight | kg | one hundred fifty | 200 | 285 | 350 | 450 | 600 | 830 | 830 | 1050 | 1250 | 1350 |