Foods Processing Chiller Box Sort Drinking water Chiller
Welcome to pay a visit to our manufacturing facility in ZheJiang
As an industrial drinking water chiller, this h2o cooled drinking water chiller has the adhering to characteristics: Chiller, drinking water chiller, drinking water cooled chiller
1. CZPT potential: nine.8kw~123kw
two. Typical situations: Chilled drinking water inlet temperature is twelve levels, outlet temperature is seven levels. Ambient temperature 35 degrees.
3. Running selection: Chilled drinking water temperature nine~twenty levels.
four. Input power: 3P-380V-50Hz, Allowable fluctuate voltage: ± ten%, allowable voltage difference in period: ± 2%.
five. Measuring sound location: 2m ahead and 1.5m substantial in front of chiller with average measurement on four proportions.
6. Acknowledge orders for unique needs.
seven. Scroll hermetic compressor worldwide brand name-free routine maintenance.
eight. CZPTtrical factors and refrigeration factors are utilized from world-renowned brand.
9. CZPT and durable style, with stainless metal water tank and higher-raise pumps.
ten. Wide assortment of variable chilled drinking water temperature to fulfill the industrial needs during entire 12 months.
11. Created as an independent refrigeration circuit, every compressor corresponding to one particular refrigeration circuit.
12. CZPTly decide on to use environmentally R407C or R134A refrigerant.
Foodstuff Processing CZPT Technique
Drinking water Cooled Box Chiller Photo Reference.
H2o Cooled Box Chiller Model Listing
DSP- | ||||||||||||
Type | 05WSZ | 08WSZ | 10WSZ | 12WSZ | 15WSZ | 20WDZ | 25WDZ | 30WDZ | 40WQZ | 50WQZ | ||
Nominal cooling potential | kW | 15.nine | 28.six | 31.7 | 36.three | forty six. | sixty three.four | 72.6 | 91. | 130. | a hundred and fifty. | |
10fourkcal/h | 1.4 | two.five | 2.seven | three.1 | four. | five.five | six.2 | seven.eight | eleven.two | twelve.9 | ||
(kW) CZPT electrical power | 3.8 | five.seven | seven.2 | 8.4 | 11.two | 14.five | sixteen.two | 22.3 | 28.nine | 33.three | ||
(A) CZPT operating present | 7.8 | 11.one | 13.nine | fifteen.five | 22.8 | 27.eight | 29.8 | 45.six | fifty five.5 | sixty one.4 | ||
CZPT | Amount | one | one | 1 | 1 | one | 2 | two | two | four | 4 | |
(kW) CZPT enter power |
three.two | four.9 | 6.5 | 7.three | ten.one | thirteen. | 14.7 | 20.one | 25.nine | 29.three | ||
(A) Rated Recent | six.nine | nine.eight | twelve.six | 13.six | twenty.nine | 25.two | 27.2 | 41.8 | 50.three | 54.4 | ||
Evaporator | Kind | Pipe dry higher effectiveness warmth exchanger | ||||||||||
(L/min) Stream | 46 | 82 | 91 | 104 | 132 | 182 | 208 | 261 | 373 | 430 | ||
Interface measurement | DN32 | DN32 | DN40 | DN40 | DN50 | DN65 | DN65 | DN65 | DN65 | DN65 | ||
Condenser | Kind | Pipe dry substantial effectiveness heat exchanger | ||||||||||
(L/min) Movement | 55 | ninety six | 109 | a hundred twenty five | 161 | 219 | 250 | 318 | 447 | 514 | ||
Interface dimension | DN32 | DN32 | DN40 | DN40 | DN50 | DN65 | DN65 | DN65 | DN65 | DN65 | ||
Chilled water pump | Sort | , Large performance,reduced sounds centrifugal h2o pump | ||||||||||
(kW) Input electrical power | .55 | .75 | .75 | 1.10 | 1.ten | 1.50 | 1.fifty | two.20 | 3.00 | 4.00 | ||
(mH2) Head | 22 | twenty five | 22 | 25 | 23 | 22 | 22 | 22 | 22 | 22 | ||
(L) Nominal tank volume | 80 | 115 | one hundred thirty | 130 | 210 | 230 | 250 | 310 | 330 | 370 | ||
Overall dimensions | (mm) Duration | 1300 | 1300 | 1350 | 1350 | 1500 | 2100 | 2100 | 2300 | 2800 | 3000 | |
(mm) Width | 750 | 850 | 850 | 850 | 900 | 1050 | 1050 | 1200 | 1600 | 1600 | ||
(mm) Peak | one thousand | a thousand | 1100 | 1100 | 1100 | 1300 | 1300 | 1300 | 1500 | 1500 | ||
excess weight | (kg) CZPT fat | a hundred and fifty | two hundred | 285 | 350 | 450 | 830 | 1050 | 1250 | 1350 | 1550 | |
(kg) Working bodyweight | 230 | 315 | 415 | 480 | 660 | 1060 | 1300 | 1560 | 1680 | 1920 |