Single Screw Compressor Water Cooled Industrial Liquid Chiller

Single Screw Compressor Water Cooled Industrial Liquid Chiller

CZPT Features
1. Twin screw compressor brand is utilized, with large effectiveness, minimal noise amount, considerably less donning and prolonged operation time.

two. Four phase volume manage or %-one hundred% automated regulation.

three. Use PLC microcomputer control from Germany SIEMENS. Liquid crystal display contact display screen, equally English and Chinese human-machina intertace.

four. Perfect breakdown defense: higher and reduced strain safety, air discharge security, oil stage safety, drinking water circulation safety, reverse and lack phase security, chilled water anti-freezing safety, cooling water overheat safety.

 

Item choices

1. Salt h2o evaporator

two. Stepless strength regulation

three. Whole heat recovery/partial warmth restoration

4. Pump handle

5. Special energy offer

6. Remote interaction connector

 

Item specfication

Refrigerant: R22/R407C/R410A/R134A

Evaporator max water force drop: one.0Mpa

Evaporator: fouling issue .018mtwo.ºC/KW

Energy source: 380V/3P/50Hz

Allowable voltage fluctuate: ±5%

Allowable frequency fluctuate: ±2%

The unit utilizes substantial effectiveness warmth exchanger with innovative, special form design and style and programs. Models can be mounted right on the roof, or other nicely-ventilated place outdoor, with out a independent room, room saving construction. Compact shape, physical appearance, device uses “W” type coil layout, room utilization, tiny unit dimensions, in order to adapt to the out of doors weather problems to guarantee that the unit has a excellent running final results throughout the daily life cycle.

CZPTy pick to use environmentally R407C, R134A or R410A refrigerant ect.

There may possibly be modify of the dimensions without pre discover. For accurate you are welcome to ask us for installing drawing.

CZPT
Pick semi-shut 5:6 asymmetric twin-screw compressor from planet-renowned brand name. The possibility of shaft seal leakage is zero. Using a rotating exhaust layout, the lastest growth of the fourth generation line, improve the circumference speed, outstanding style of gear so that the device has higher compression performance. Motor chamber compression chamber integrally forged, higher precision. Double stress compensated rotor housing, quite sturdy, no expansion even in the point out of higher force, and it effectively lowers the sound.

Heat exchanger
The condenser and evaporator of this sequence unit adopts shell and tube heat exchanger, utilizing new higher productive heat exchanger construction. Warmth exchanger adopts the most advanced and effcient heat exchanger tube bundle with distinctive geometric traits and increased tube nucleate boiling needed vaporization core, reinforce the fluid in the tube and hold off perturbationat the identical time, the drinking water side fouling, warmth transfer enhanment, the within wall in purchase to get the very best performace, comparade to the earlier style, the special layout of the heat transfer effectiveness is improved by 30%.
Evaporator evapotation tube with inner grooved on outer concave tooth enhanced heat transfer technology, condenser tube with inner grooved cutter tooth technologies, improves the evaporator and condenser heat transfer effectiveness and the evaporation temperature, and boost the power effectiveness ratio for the device.

PLC
A great Chinese-English interactive interface is to obtain computerized control function just before the Liquid crystal display screen genuine-time statues of the device work, exact monitoring device working at optimun point out, the contact pannel sealed, watertight, dustproof, corrosion-resistant, extended-important daily life. Outfitted with cooling pumps, cooling drinking water pumps and cooling tower fan interlock handle function.

CZPT parameter

Air cooled screw(heat) chiller(single compressor) technical parameter

VA-

Kind

85S

115S

150S

160S

200S

220S

255S

270S

300S

320S

Nominal cooling capability

kw

eighty five.

one hundred fifteen.

one hundred fifty.

a hundred and sixty.

200.

220.

255.

270.

300.

320.

104 kcal/h

7.3

9.9

twelve.9

thirteen.eight

17.2

18.9

21.9

23.two

twenty five.8

27.five

Nominal heating ability

kw

92.

one hundred thirty five.

a hundred and seventy.

185.

230.

250.

290.

three hundred.

330.

360.

104 kcal/h

eight.two

eleven.six

fourteen.six

fifteen.nine

19.8

21.5

24.9

twenty five.eight

28.4

31.

Running manage strategy

Use PLC microcomputer management

Power CZPT

380V/3N/50HZ

CZPTtup sort

Y-

CZPT energy

kw

30.8

forty.9

50.three

fifty nine.6

70.six

76.7

eighty five.

88.five

99.8

108.four

CZPT functioning recent

A

58.five

77.seven

95.five

113.2

134.one

a hundred forty five.7

161.four

168.1

189.five

206.

CZPT

Variety

Semi-shut 5:6 asymmetric twin-screw compressor

CZPT electrical power(kw)

27.five

36.five

45.five

50.

61.

66.five

seventy five.

seventy eight.5

86.five

ninety four.5

CZPT present(A)

forty six.5

sixty one.

seventy seven.

eighty four.five

103.

112.

126.

132.5

146.

159.

Heating electrical power(kw)

26.five

35.

43.5

forty eight.

fifty eight.5

sixty three.5

72.

75.five

83.

91.

Heating recent(A)

44.five

58.5

74.

eighty one.

ninety eight.five

107.

120.

127.

140.

152.

CZPT regulation

-33%-66%-100%

-twenty five%-50%-seventy five%-100%

Evaporator

Sort

Higher effectiveness dry kind shell and tube warmth exchanger

Flow(L/min)

14.6

19.eight

twenty five.eight

27.five

34.4

37.8

43.eight

forty six.4

51.five

fifty five.

Drinking water pressure fall(kPa)

forty five.

forty five.

forty five.

forty eight.

48.

48.

fifty.

fifty.

50.

fifty.

Interface measurement

DN65

DN80

DN100

Condenser

Type

Large performance fin kind heat exchanger

Fan amount

six

eight

8

6

six

6

six

six

eight

8

Stand-by yourself electricity

.six

.six

.6

one.6

one.6

one.7

1.7

one.seven

1.seven

1.7

Refrigerant

Variety

R22

Refrigerant quantity(kg)

17.

23.

thirty.

32.

40.

forty five.

52.

fifty five.

sixty.

65.

Total proportions

Duration(mm)

2500

2950

2950

3200

3500

3500

3700

3700

4000

4000

Width(mm)

1400

1400

1400

2200

2200

2200

2200

2200

2200

2200

Peak(mm)

1925

2100

2250

2150

2150

2200

2250

2350

2150

2250

Fat

CZPT fat(kg)

1900

2000

2200

2600

2850

3000

3200

3500

3800

3950

Working fat(kG)

2200

2300

2500

2900

3150

3300

3500

3800

4100

4250

CZPT situation: Chilled water inlet/outlet temperature 12/seven ºC, ambient dry bulb temperature 35ºC

Heating situation:Hot water outlet temperature 45ºC, ambient dry bulb temperature 7ºC, ambient soaked bulb temperature 6ºC

H2o cooled screw chiller(one compressor) technological parameter

VW-
Kind 100S 135S 175S 190S 235S 260S 300S 320S 350S 380S
Nominal cooling capability kw 98. 135. 175.6 191.1 233.3 255.six 301.one 317.8 347.eight 380.
104 kcal/h eight.four 11.six 15.1 16.4 20.one 22. 25.9 27.three 29.nine 32.7
Working control strategy Use PLC microcomputer handle
Energy CZPT 380V/3N/50HZ
CZPTtup variety Y-△
CZPT Variety Semi-shut 5:6 uneven twin-screw compressor
Enter electricity(kw) 23. thirty. 39. 42. fifty one. fifty six. sixty three. sixty six. seventy three. 80.
Rated current(A) 39.two fifty one.six 64.7 71. 86.four 94.1 a hundred and five.9 111.4 122.7 133.eight
CZPT regulation -33%-66%-one hundred% -25%-fifty%-75%-one hundred%
Evaporator Variety Large performance dry kind shell and tube warmth exchanger
Flow(mthree/h) sixteen.nine 23.2 30.two 32.9 40.1 44. fifty one.eight fifty four.7 fifty nine.eight 65.4
H2o stress drop(kPa) 45. 45. 48. 48. fifty. fifty. 50. fifty five. fifty five. fifty five.
Interface measurement DN65 DN80 DN100 DN125
Condenser Type High effectiveness shell and tube heat exchanger
Stream(m3/h) twenty.eight 28.4 36.nine forty.one forty eight.nine fifty. fifty. fifty five. 55. fifty five.
Water pressure fall(kPa) 42. 42. 45. 45. forty eight. 48. 48. fifty two. 52. 52.
Interface measurement DN65 DN80 DN100 DN125
Refrigerant Kind R22
Refrigerant volume(kg) sixteen. 22. 25. thirty. 35. 40. forty five. fifty. 53. 56.
General dimensions Duration(mm) 2450 2450 2700 2850 2850 2850 2850 3250 3250 3250
Width(mm) 660 660 660 890 890 920 920 920 960 985
Height(mm) 1450 1590 1590 1600 1690 1690 1690 1690 1750 1750
Fat CZPT bodyweight(kg) 850 1050 1150 1270 1340 1430 1640 1710 1780 1850
Running fat(kG) 900 1150 1300 1420 1540 1670 1890 1930 1970 2050

CZPT issue: Chilled water inlet/outlet temperature 12/7 ºC, cooling drinking water inlet/outlet temperature 30ºC/35ºC
Temparature term: Chilled h2o outlet temperature 5ºC~15ºC cooling h2o inlet temperature 19ºC~33ºC.

 

Single Screw Compressor Water Cooled Industrial Liquid Chiller