We can personalize distinct types of chillers and central air conditioners according to buyer ask for, welcome to get in touch with us for specifics, we will offer expert solutions for you.
CE Air CZPT Laser Small Chiller for Water Cold
Profile
Solution Name: Air Cooled Box Sort Water Chiller (created-in h2o tank and pump)
CZPT Capacity: seven.two-117.six KW
Merchandise Category: [SG Collection Scroll Kind Drinking water Chiller ]
Chilled Water Outlet Temperature:7ºC
Software: Extensively utilised in lodges, theaters, purchasing malls, small office properties and other spots
Attribute
Higher Dependability
Scroll compressor has 60% less inside elements than reciprocating compressor. The scroll compressor is made to avoid liquid refrigerant and impurities from entering the compressor.
Outfitted with a microcomputer control unit to safeguard the compressor from failure. The torque modify of the scroll compressor is one/3 of the reciprocating compressor.
Large Performance
The scroll compressor is rotary volume layout, with small clearance quantity, modest friction loss and large operating effectiveness. The unit adopts a mixture of a number of compressors, which has high effectiveness in portion load procedure.
CZPT
The refrigerant circuit and management circuit are entirely impartial ,can be used alternately according to loading issue, which can successfully prolong the service lifestyle. It has the positive aspects of substantial efficiency, low energy intake, lower noise, reduced vibration, put on resistance and high reliability.
Fin-Coil Condenser
Adopts fin-coil condenser , the heat exchange tubes are outer fin threaded copper tube. The finned condenser has a huge warmth transfer coefficient and large heat trade efficiency. With compact framework, gorgeous physical appearance, gentle fat , it is straightforward to put in, work, and sustain, can successfully make certain the protected operation of the refrigeration method.
Evaporator
Shell and tube type evaporator adopts inner fin copper tube, and is geared up with refrigerant shunting gadget which can evenly distribute the refrigerant to each heat exchange tube, enhance heat exchange effectiveness. For multi-compressor chiller, every single compressor is equipped with an evaporator and a condenser, the a few represent an impartial refrigeration program. Because of to structural factors, the water paths of the two evaporators are often related, but the refrigeration circuits are independent. The exterior of the evaporator is affixed with thermal
Thermal growth valve
The globe-renowned model Emerson thermal expansion valve is used for increased handle accuracy, wider adjustment range and quicker response. Beneath any operating problems, the heat exchange area of the evaporator can be entirely utilized, the warmth trade is far more ample, and the effectiveness is larger, which can guarantee the dependability of the refrigeration system.
Handle Technique
CZPTt-Quit security, management compressor commencing frequency
Equivalent environment of compressor commence-stop moments and managing time
Power-off memory, historic fault question operate
Overload safety, phase sequence security, anti-frozen safety, higher and low strain protection, exhaust temperature defense and other protections.
Inlet and outlet h2o temperature manage
Reserved joint handle speak to of chilled water pump
Specification
Air-Cooled Scroll Chiller | Requirements | ||||||||||||
SKA-Product | 12.5SX | 15SX | 20DX | 25DX | |||||||||
Refrigerant | R22 | R407C | R134a | R22 | R407C | R134a | R22 | R407C | R134a | R22 | R407C | R134a | |
Rated CZPT Capability | ×1000kcal/h | 26.3 | twenty five.two | 17.2 | 33.seven | 32 | 22.one | forty six.2 | 43.8 | 29.six | 52.6 | fifty.four | 34.4 |
KW | thirty.6 | 29.three | twenty | 39.two | 37.two | twenty five.7 | fifty three.6 | 51 | 34.four | 61.2 | fifty eight.six | forty | |
Energy CZPT | 380V-3N-50Hz | ||||||||||||
Enter power (KW) | eleven.6 | eleven.5 | 8.eight | 14.9 | 14.8 | eleven | 19.7 | 19.5 | fourteen.nine | 21.7 | 21.5 | 16.1 | |
CZPT existing (A) | 21.three | 21.four | 17.one | 29.two | 30.3 | 23.7 | 36.eight | 37.two | 32.6 | 39.6 | 39.eight | 31.2 | |
CZPT System | Section sequence safety,overcurrent protection,Anti frozen security,large and low voltage defense,Gasoline outlet temperature protection,h2o movement safety | ||||||||||||
CZPT | Input power (KW) | eight.8 | 8.seven | six | 11.9 | 11.8 | 8 | fifteen.6 | fifteen.4 | 10.eight | seventeen.6 | 17.4 | 12 |
Current (A) | 15.6 | 15.seven | eleven.4 | 23.2 | 24.3 | seventeen.7 | 28.4 | 28.eight | 24.two | 31.two | 31.four | 22.8 | |
chilled water pump | Input power (KW) | one.5 | 1.5 | 1.5 | one.5 | ||||||||
Recent (A) | three | 3 | three | 3 | |||||||||
Number of CZPT Circuit | 1 | 2 | |||||||||||
Capacity Control (%) | -a hundred | -fifty-one hundred | |||||||||||
Condenser | Finned Variety | ||||||||||||
CZPT supporter | Enter power (KW) | one.3 | 1.5 | two.6 | 2.6 | ||||||||
Present (A) | two.7 | 3 | 5.four | five.four | |||||||||
Evaporator | Shell-and-Tube Kind | ||||||||||||
Dia.of pipe to Evaporator (inch) | 1-one/2″ | 2″ | 2″ | 2″ | |||||||||
Chilled Water Stream (L/min) | 87.7 | eighty four | 57.4 | 112.4 | 106.6 | seventy three.seven | 153.6 | 146.two | 98.six | one hundred seventy five.4 | 168 | 114.eight | |
Working noise (dBA) | 65 | 67 | 67 | sixty seven | |||||||||
Tank Volume (L) | one hundred sixty | one hundred sixty | 210 | 210 | |||||||||
Complete Weight (kg) | 470 | 530 | 680 | 700 | |||||||||
Outline dimension (L*W*H)mm | 1600*a thousand*1650 | 1600*one thousand*1650 | 2050*1100*1650 | 2050*1100*1650 | |||||||||
Observe: one.Rated cooling capacity based on: Evaporator water inlet and outlet temperature 12ºC/7ºC,Ambient temperature range:35ºC, Fouling coefficient is .088m2.ºC/KW two. Chillled h2o temperature assortment: 5ºC~20ºC 3. Cheapest ambient temperature range: 0ºC four. Specs and proportions are subject to change owing to product advancement without having notice. |
Applications
There are many aspects influencing the refrigeration scheme. Each and every scheme has its own benefits and down sides. From the viewpoint of thermodynamics, what is pursued is the rationality of the strength utilised in the method (strength degree utilization method) and perfection—cooling software efficiency From an economic point of see, the system is needed to get the optimum income with a bare minimum investment decision. From the viewpoint of thermal economics, CZPT researches the quantitative analysis index of thermal financial coefficient, and utilizes this index to improve the industrial refrigeration scheme to propose the most cost-effective energy-saving industrial refrigeration program remedy.
CZPT industrial chiller primary application industry:
1. CZPT molding, injection molding, extrusion molding, blowing, thermoforming, pipe, profile, BOPP film, plastic sheet
two. CZPT, chemical fiber, pharmaceutical, foods processing, cosmetics, wine, paper, printing
3. CZPT chopping, non-slicing, casting
four. Laser engineering, welding, area remedy, electroplating, electrophoresis
five. CZPT tools, electronics market, circuit board generation, electronic chip production
6. Aluminum profile, aluminum alloy, tempered glass, coated glass generation
seven. CZPTsonic cleansing, jewellery processing
eight. CZPT, fur processing, ink production
nine. Photo voltaic photovoltaic, concrete watering, electrical power
ten. Greenhouse planting, aquaculture, and so forth.
Instances
Certificates
CE&ISO9001&ISO14001&BV&AHRI
Right after-sales provider
twelve months good quality warranty given that the date of delivery.
Free of charge to substitute new chillersif top quality issues.
Cost cost to get extra parts with Chillers from CZPTr if essential.
Video clip technological help
On the web assistance(E-mail, Skype, Wechat, Whatsapp, Telephone…)
Engineers offered to service equipment overseas if required
Essential info to Quote
1. What is your cooling capability? _____ Kcal/hr or _____KW or _____RT?
two. What is actually your energy supply? For illustration: 3800V-50Hz-3N (N=Period )
3. What refrigerant variety do you demand? R22 or R134a or R407c?
four. What is your ambient temperature? And what is your chiller inlet and outlet h2o temperature?
5. Which sector do you use the chiller in?
FAQ
Q1: Are you a manufacturer?
A1: Indeed, we have more than 10 several years in h2o chiller enterprise. New plant was bulit in 2017 in HangZhou CZPT&Technological CZPT Zone. Welcome to visit us anytime!
Q2: Could you aid us to recommend the model for our undertaking?
A2: Yes, we have engineer to examine the specifics and make the plan for you. Primarily based on the following:
one)CZPT capacity
2) Refrigerant
three) Ambient temperature
4)Voltage
5) For what market
6)The developing drawing(if you have)
seven)Any other unique needs.
Q3: How to ensure your product with very good good quality?
A3: We use the well-know brand add-ons, these kinds of as CZPT, CZPT, danfoss compressor, Emerson growth Valve, Siemens controller. All CZPTR chillers are manufacturing unit examined below load conditions to guarantee excellent high quality and straightforward installation for consumers.
This fall: What is actually the warrenty?
A4: 1 year warrenty for free of charge if confirmed by each facet injury in the top quality cause.
Q5: Whats your payment phrase?
A5: We acknowledge TT, LC, CZPT CZPT, and many others. Usually, 30% deposit for generation, 70% stability ahead of cargo.
Q6: How can I place an purchase?
A6: Contact us via made in China or speak to beneath details.
Ms. Livia
Tel: 13595716431