CZPT Saving 110kw 150hp CZPT Air CZPT with Reduced Noise
one . Our manufacturing unit and workshop for CZPT Conserving 110kw 150hp CZPT Air CZPT with Reduced Noise
two. solution introduction for CZPT Preserving 110kw 150hp CZPT Air CZPT with Low Noise :
Software :
Air compressor is basic sector tools, is the CZPT largest electrical power resource, is also the procedure air source with multiple employs, extensively utilised in mining exploitation, oil drilling, iron and metal metallurgy, electric powered power, shipbuilding, electronics creation, petroleum chemical market, mild industry, equipment manufacturing, meals and drugs, transportation services, shipping docks, casting coating, vehicle industry, aerospace, army technological innovation, infrastructure and so on fields.
Characteristics: undertake twin rotor/screw air end for compression air system.
3. Advantages of CZPT Preserving 110kw 150hp CZPT Air CZPT with Lower Sounds :
one. Approved by ISO9001certificate, SGS, CE and etc..
two. Undertake the most superior technology and world CZPT brand name of twin rotor/ screw engin air end in planning and manufacturing, no leakage, guarantee substantial air discharge and low energy intake.
three. Adopt large high quality electric motor with SKF bearing, IP54, convenient maintenance and lengthy use existence.
four. Undertake globe CZPT brand of air intake filter, oil filter, air and oil separator, comprehend high filtration accuracy, compressed air oil material underneath 3ppm, reach to international sophisticated CZPT degree.
five. Equip with the most superior air handle technique. Adopt air consumption valve, intelligent control method and pressure sensor merged manage method, can function by ON and OFF two level, stepless air ability control system, time-delay end and automatically commence device three air capacity control strategies, can satisfy distinct clientele desire.
6. CZPT microcomputer handle system, Chinese and English language operation interface, malfunction display, alarm and device cease instantly.
seven. Undertake large top quality and globe CZPT manufacturer of primary elements, like British isles APD oil filter, CZPTica AMOT temperature controlling valve, SCHNEIDER electric elements and and many others., substantial performance, reliable and extended use daily life.
eight. Equip with after air compression cooler combination with the air and drinking water separator, compact framework and save space, avoid leakage and improve the air and water separating efficiency mainly.
4. Parameters of CZPT Saving 110kw 150hp CZPT Air CZPT with Lower Noise :
Observe: F stands for wind cooling method, W stands for water cooling method. Other variety of stress price equipment CZPT.
Model | TKL-2F | TKL-3F | TKL-4F | TKL-5F | TKL-7F | TKL-11F | TKL-15F | TKL-18F | TKL-22F | TKL-30F | TKL-37F | TKL-45F/W | TKL-55F/W | TKL-75F/W | TKL-90F/W |
Air displacemen/ Exhause strain (m3/min/Mpa) |
.33/.seven | .forty three/.seven | .six/.7 | .eight/.seven | one.23/.seven | one.65/.7 | 2.seven/.seven | three./.7 | 3.6/.7 | five.two/.seven | six.six/.7 | 7.eight/.seven | ten.one/10.seven | thirteen.5/.7 | sixteen.three/.7 |
.33/.8 | .4/.8 | .55/.8 | .seven/.8 | one.sixteen/.8 | 1.sixty two/.eight | two.5/.8 | 2.92/.eight | three.fifty three/.8 | five./.8 | 6.three/.8 | seven.five/.eight | nine.eight/.8 | 12.three/.eight | 15.6/.8 | |
.twenty five/1. | .36/one. | .5/one. | .sixty five/one. | 1.02/one. | one.4/one. | two./1. | two.seven/1. | 3.two/one. | four.five/one. | 5.6/one. | 6.eight/1. | eight.8/1. | 11./1. | 14.2/1. | |
.22/one.3 | .three/one.three | .45/1.3 | .6/one.3 | .86/one.3 | one.21/1.three | 1.8/one.three | 2.2/one.three | 2.four/1.three | 3.five/1.3 | four.8/1.three | five.8/1.3 | 7.2/one.3 | nine./1.three | 11.5/one.three | |
Electrical power/ (Kw) | 2.two | 3 | 4 | five.five | 7.5 | eleven | fifteen | 18.5 | 22 | 30 | 37 | 45 | fifty five | seventy five | ninety |
Ooltage (V/Hz) | 380V/50Hz | ||||||||||||||
Noise (±3,dBa) | sixty three | sixty three | sixty five | 65 | 67 | 67 | 68 | 70 | seventy two | seventy three | seventy four | 75 | 76 | 78 | 78 |
Exhaust temprature | Wind cooling sort <=CZPTal temperature+13ºC, Water cooling type <=40ºC, | ||||||||||||||
Outlet pipe size | one/2″ | one/2″ | 1/2″ | one/2″ | 1/2″ | three/4″ | 1″ | 1″ | 1″ | one 1/2″ | 1 1/2″ | one 1/2″ | DN50 | DN50 | DN50 |
Excess weight (Kg) | 260 | 280 | three hundred | 350 | 360 | 400 | 430 | 590 | 650 | 950 | 980 | 1050 | 1850 | 1900 | 2100 |
Proportions (mm) | 800*760*1102 | 800*760*1102 | 800*760* 1102 |
800*760* 1102 |
800*760* 1102 |
950*760*1202 | 900*1000*1290 | belt type 900*1000*1290 | 1500*950*1280 | 1600*1100*1430 | 1900*1150*1500 | 2000*1150*1680 | |||
strait variety 1350*850*1257 |
Model | TKL-one hundred ten F/W |
TKL-132 F/W |
TKL-a hundred and sixty F/W |
TKL-185 F/W |
TKL-200 F/W |
TKL-220 F/W |
TKL-250 F/W |
TKL-280 F/W |
TKL- 315W |
TKL- 355W |
TKL- 400W |
TKL- 450W |
TKL- 500W |
TKL- 560W |
TKL- 630W |
Air displacemen/ Exhause strain (m3/min/Mpa) |
20.4/.seven | 24/.7 | 27.8/.7 | 32.5/.7 | 35/.seven | forty.7/.7 | 45.3/.7 | fifty one.5/.seven | fifty seven/.seven | 68/.7 | 73.6/.7 | eighty three/.seven | ninety/10.7 | 101/.7 | 111/.7 |
twenty/.8 | 23/.8 | 27.1/.8 | thirty.five/.eight | 33.3/.8 | 38.2/.eight | forty three/.8 | fifty.five/.8 | 55.five/.8 | sixty six.2/.eight | seventy one.4/.8 | eighty two/.8 | 89/.8 | a hundred/.eight | 110/.8 | |
17.eight/one | 21/one. | twenty five.2/1. | 27/one. | 30.6/1. | 34.five/one. | 38.1/one. | 43/1. | fifty.five/1. | 55.six/one. | 62/one. | 73/one. | eighty/1. | 86/one. | ninety five/one. | |
14.5/one.3 | 18.one/1.three | 21.2/1.3 | 23.6/one.3 | 26.three/one.3 | 29.8/1.3 | 35/one.three | 38.3/1.three | forty two.1/1.three | forty six.five/one.three | fifty two.5/one.3 | sixty/1.3 | 68/one.3 | |||
Electricity/ (Kw) | one hundred ten | 132 | one hundred sixty | 185 | two hundred | 220 | 250 | 280 | 315 | 355 | four hundred | 450 | 500 | 560 | 630 |
Ooltage (V/Hz) | 380V/50Hz | 380-10000V/50Hz | |||||||||||||
Noise (±3,dBa) | seventy eight | 78 | 78 | 78 | 80 | eighty | eighty | eighty | 80 | eighty | eighty two | eighty two | eighty two | 82 | eighty two |
Exhaust temprature | Wind cooling type <=CZPTal temperature+13ºC, Water cooling type <=40ºC, | ||||||||||||||
Outlet pipe size | DN80 | DN80 | DN80 | DN80 | DN100 | DN100 | DN100 | DN100 | DN125 | DN125 | DN150 | DN150 | DN150 | DN200 | DN200 |
Excess weight (Kg) | 3300 | 3500 | 4000 | 4600 | 4700 | 5100 | 5100 | 5500 | 7500 | 8300 | 8400 | 9000 | 9500 | 10000 | 10000 |
Proportions (mm) | F 2800*1540*1900 | F 2800*1540*1900 | F 3150*1650*1900 | F 3100*1940*2389 | F 3400*2000*2330 | 4500*200*2462 | 4650*2340*2835 | ||||||||
W 2400*1540*1900 | W 2400*1540*1900 | W 2600*1700*1980 | W 2600*1700*1980 | W 3200*1800*2125 |
three. Certification and patents of CZPT Saving 110kw 150hp CZPT Air CZPT with Low Noise :
FAQ:
Q1: Are you factory or trade company?
A1: We are manufacturing facility.
Q2: Warranty phrases of your device?
A2: One 12 months guarantee for the device and specialized assistance according to your wants.
Q3: Will you give some spare elements of the devices?
A3: Yes, of training course.
This fall: How prolonged will you take to arrange production?
A4: 380V 50HZ we can shipping and delivery the products inside 20 days. Other electricity or other colour we will shipping and delivery within thirty times.
Q5: Can you settle for OEM orders?
A5: Yes, with professional design team, OEM orders are highly welcome!