Model | Operating Strain | Capacity | Motor Electrical power | Noise dB(A) |
Inlet and outlet pipe diameter of cooling h2o |
CZPT water volume |
Dimension(mm) | Internet Fat | Air Outlet Pipe Diameter | ||||
Psi | bar | Cfm | m3/min | kw/hp | Drinking water temp.32ºC |
L | W | H | KGS | ||||
T/H | |||||||||||||
SGM08 | 116 | 8 | forty.65 | 1.15 | 7.five/10 | fifty eight | 3/four” | two | 1550 | 775 | 1445 | 630 | three/four” |
a hundred forty five | 10 | 36.01 | one.02 | ||||||||||
SGM11 | 116 | eight | fifty four.73 | one.55 | 11/fifteen | 58 | 3/four” | 2.five | 1080 | 750 | 1571 | 280 | 3/four” |
one hundred forty five | ten | 46.61 | 1.32 | ||||||||||
174 | twelve | 36.02 | 1.02 | ||||||||||
SGM15 | 116 | 8 | eighty four.74 | 2.40 | 15/twenty | sixty three | one” | three.5 | 1080 | 750 | 1571 | three hundred | one” |
one hundred forty five | ten | seventy four.86 | 2.12 | ||||||||||
174 | 12 | 56.85 | one.61 | ||||||||||
SGM18 | 116 | eight | 109.46 | 3.10 | eighteen.5/25 | sixty five | 1″ | four | 1380 | 850 | 1185 | 430 | one” |
one hundred forty five | ten | 92.51 | two.62 | ||||||||||
174 | 12 | seventy five.21 | 2.13 | ||||||||||
SGM22 | 116 | eight | 123.59 | 3.50 | 22/30 | sixty five | 1″ | 5 | 1380 | 850 | 1185 | 450 | one” |
one hundred forty five | 10 | a hundred and ten.52 | 3.thirteen | ||||||||||
174 | 12 | ninety two.16 | two.sixty one | ||||||||||
SGM30 | 116 | 8 | 176.55 | 5.00 | thirty/forty | 66 | 1 one/four” | 7 | 1380 | 850 | 1185 | 500 | 1 1/2″ |
a hundred forty five | 10 | 148.30 | four.20 | ||||||||||
174 | twelve | 112.29 | 3.eighteen | ||||||||||
SGM37 | 116 | 8 | 215.39 | six.10 | 37/50 | sixty seven | one 1/four” | nine | 1500 | a thousand | 1345 | 650 | one 1/2″ |
one hundred forty five | 10 | 184.32 | five.22 | ||||||||||
174 | 12 | 169.84 | 4.81 | ||||||||||
SGM45 | 116 | 8 | 257.76 | 7.30 | forty five/60 | 68 | one 1/two” | 10 | 1500 | a thousand | 1345 | 680 | 2″ |
145 | 10 | 216.45 | six.13 | ||||||||||
174 | twelve | 199.50 | 5.65 | ||||||||||
SGM55 | 116 | 8 | 338.98 | 9.60 | 55/75 | 70 | one 1/2″ | twelve | 1800 | 1250 | 1670 | 1150 | two” |
a hundred forty five | 10 | 303.67 | eight.60 | ||||||||||
174 | 12 | 262.00 | seven.42 | ||||||||||
SGM75 | 116 | 8 | 441.38 | 12.50 | seventy five/a hundred | 73 | 1 one/2″ | eighteen | 1800 | 1250 | 1670 | 1200 | two” |
145 | ten | 403.24 | 11.forty two | ||||||||||
174 | twelve | 347.10 | 9.eighty three | ||||||||||
SGM90 | 116 | eight | 575.55 | 16.30 | ninety/one hundred twenty | 73 | two” | twenty | 1800 | 1250 | 1670 | 1350 | two one/2” |
145 | 10 | 512.70 | 14.52 | ||||||||||
174 | 12 | 434.31 | 12.30 | ||||||||||
SGM110 | 116 | 8 | 685.01 | 19.40 | 110/one hundred fifty | 78 | 2″ | 24 | 2300 | 1470 | 1840 | 1800 | two one/2” |
one hundred forty five | ten | 596.74 | sixteen.90 | ||||||||||
174 | 12 | 533.18 | fifteen.10 | ||||||||||
SGM132 | 116 | eight | 784.24 | 22.21 | 132/a hundred seventy five | seventy eight | 2″ | thirty | 2300 | 1470 | 1840 | 1850 | 2 one/2” |
145 | ten | 719.62 | twenty.38 | ||||||||||
174 | twelve | 645.82 | 18.29 | ||||||||||
SGM160 | 116 | eight | 1018.69 | 28.eighty five | 160/two hundred | seventy eight | 2 1/two” | 35 | 2300 | 1470 | 1840 | 2000 | three” |
145 | 10 | 865.80 | 24.52 | ||||||||||
174 | twelve | 782.82 | 22.17 | ||||||||||
SGM200 | 116 | 8 | 1293.41 | 36.sixty three | two hundred/270 | seventy eight | three” | 43 | 3150 | 1980 | 2152 | 3500 | four” |
a hundred forty five | 10 | 1154.64 | 32.70 | ||||||||||
174 | 12 | 978.79 | 27.72 | ||||||||||
SGM250 | 116 | eight | 1514.09 | 42.88 | 250/350 | 78 | 3″ | 53 | 3150 | 1980 | 2152 | 3800 | four |
145 | ten | 1377.09 | 39.00 | ||||||||||
174 | twelve | 1223.14 | 34.64 | ||||||||||
Motor CZPT Course: IP23/IP54/IP55 or as for each your essential | |||||||||||||
Voltage: 380V/50Hz/3ph, 380V/60Hz/3ph, 220V/50Hz/3ph, 220V/60Hz/3ph, 440V/50Hz/3ph, 440V/60Hz/3ph, or as for each your requests. |
Q1: Will the lubricated water rust the air system?
The pure drinking water which conforms the consuming CZPT is utilized in the drinking water lubricated oil cost-free compressor, and the components of components are 304/316 stainless steel. So the h2o will not rust tge air technique.
Q2: Will the drinking water influence the services lifestyle of bearing?
Use tZheJiang ometer SIC bearing and ceramic bearing, and the h2o as the lubricant for them straight, so there is no dilemma for the bearing.
Q3: Will the h2o accumulate the sediment ?
The solution is no. The system use pure water which conforms to the drinking CZPT and the h2o is circulating in the system. Every two hundred hrs, the method can immediately change drinking water to make confident the calcium articles in the pure drinking water will not increase. In addition, the working temperature of air finish is not larger than 50ºC.
This autumn: Will the performance of drinking water lubricated oil free of charge compressor decrease gradually?
The technological innovation of air finish is from Japan, we are the specialist production business who know the real essence of the single screw air stop. We promised our customers 2 years of guarantee for air end, and the service existence is above 20 many years. The effectiveness will not decrease by much more than five%.
Q5: Does the compressed air have ample water?
The drinking water in compressed air is saturated soon after the air is compressed. The h2o content material in compressed air has nothing to do with anything at all but the temperature. The temperature of compressed air is not increased than 50ºC and its water articles is saturated at 50ºC. And the temperature of compressed air from other CZPTs is considerably far more than 50ºC, so the h2o content of water lubricated oil free compressor is reduce than other compressors.
HangZhou CZPT MECHANICAL & ELECTRIAL Products CO., LTD |
Add:#1401-1402 No.14 Constructing, Haixibaiyuecheng, No.one hundred twenty Fuxia Highway, Xihu (West Lake) Dis. District, HangZhou, ZheJiang , China
Make contact with individual: Stefanie Lin