Air-cooling industrial chiller employing innovative generation engineering, superior top quality, compact framework, beautiful look. The goods can be broadly utilised in plastics, electroplating, electronics manufacturing, pharmaceutical chemical compounds, foods processing, laser, ultrasonic amazing, printing and other industries, can properly handle the demand from customers for present day industrial mechanized production of temperature, hence tremendously enhancing the manufacturing effectiveness and product good quality.
Primary Features
one. Making use of CZPT/Darkin from Japan, CZPT from the CZPT States and other brand compressors, reduced sound and electrical power conserving, More tough
2. Adopt fin and tube condenser, cooling influence is excellent and secure overall performance
three. Evaporator stainless metal h2o tank, developed-in automatic h2o unit
four. Undertake imported pumps, stainless metal pump for consumers to choose from, to stop CZPTary air pollution
5. Microcomputer digital temperature controller, integrated operation, easy and sensible, high management precision
6. Making use of box composition, CNC punch push precision machining, electrostatic electricity paint, classy look, equipped with wheel so that simple to go
7. Chiller Device geared up with reverse section absence safety, motor overload protection, higher and low voltage safety, temperature security and other security protection device, produced the system a lot more steady and secure. Modest measurement, gentle fat, and compact structure
CZPT Parameters:
Parameters | Model | KDE-02A | KDE-03A | KDE-05A | KDE-06A | KDE-08A | KDE-10A | |
Rated CZPT Capacity | Kw/50Hz | 6.2 | nine. | 14.eight | 17.eight | 23.nine | 29.8 | |
Kw/60Hz | seven.1 | ten.four | 17. | twenty.five | 27.five | 34.3 | ||
USRT/50Hz | one.eight | 2.six | 4.2 | five.1 | 6.eight | 8.five | ||
USRT/60Hz | two. | two.nine | 4.eight | five.eight | 7.8 | 9.7 | ||
Kcal/h/50Hz | 5332 | 7740 | 12728 | 15308 | two 0571 | 25628 | ||
Kcal/h/60Hz | 6106 | 8944 | 14620 | 17888 | 23650 | 29498 | ||
Enter Energy | KW | two.1 | two.82 | 5. | five.6 | seven.25 | nine.15 | |
Max Operating Current | A | 15.8 | 8.eight | 13.four | 16 | twenty.nine | 26.seven | |
Electrical power | 1PH 220V 50Hz | 3PH 380V 50Hz(200V/220V/415V/460V50Hz/60Hz) | ||||||
Refrigerant | Sort | R22 (R134a/R407c) | ||||||
Management Method | Capillary | Exterior-balanced Thermostatic Enlargement Valve | ||||||
CZPT | Variety | Hermetic Rotary Type | Hermetic Scroll Variety | |||||
Power | KW | 1.five | 2.25 | 3.75 | 4.5 | 6 | seven.five | |
Condenser | Kind | Effective Aluminum Finned Copper Sleeve+Low Sounds Exterior Rotor Fan | ||||||
CZPT Air Stream | m³/h 50Hz | 2600 | 3800 | 6300 | 7600 | 15710 | 12800 | |
m³/h 60Hz | 2900 | 4300 | 7000 | 8500 | 11400 | 14200 | ||
Evaporator | Sort | Tank with Coil or Shell and Tube | ||||||
Tank Quantity | L | 30 | 60 | sixty | 70 | 150 | a hundred and eighty | |
Chilled Drinking water Flow | m³/h 50Hz | one.1 | one.5 | two.5 | three.one | four.one | five.one | |
m³/h 60Hz | one.two | 1.8 | two.9 | 3.five | four.7 | 5.nine | ||
Inlet/Outlet Pipe Dia. | Inch | one/2″ | one” | one” | 1″ | one-one/two” | one-one/two” | |
Water Pump | Energy | KW | .37 | .37 | .75 | .seventy five | .75 | 1.1 |
Elevate | M | 20 | 20 | twenty | 20 | twenty | 20 | |
Security CZPT | CZPT over heating security, above recent safety, Large/minimal voltage safety, above heating defense, flow protection, period safety, Exhausting overheat defense, anti-freezing defense | |||||||
Dimension | Length | mm | 770 | one thousand | 1120 | 1150 | 1250 | 1500 |
Width | mm | 500 | 480 | 530 | 500 | 680 | 770 | |
Top | mm | 950 | 1100 | 1200 | 1200 | 1400 | 1400 | |
Fat | KG | 95 | 128 | 172 | a hundred ninety | 310 | 350 | |
Notice | one. The above red font parameters for specific voltage model need to have to particular get CZPT capacity of R407C unit will be 5% lower than R22 unit | |||||||
2. Nominal cooling capacity calculated according to: inlet/outlet chilled fluid temperature: 17ºC/12ºC inlet/outlet cooling air temperature: 30ºC/35ºC | ||||||||
3. Doing work problem: The temperature range of chilled fluid is from 5ºC to 35ºC temperature distinction amongst inlet and outlet chilled fluid is from 3ºC to 8ºC. | ||||||||
4. It is better to run the chiller even though the ambient temperature at or under 35ºC | ||||||||
5. The electricity distribution and wiring of the installation shall be based mostly on the nameplate or installation directions of the unit. We reserve the rihgt to modify the earlier mentioned data whithout prior observe |
Function Theory
Apps
Be commonly utilised in plastics, electroplating, electronics producing, pharmaceutical chemical substances, foodstuff processing, refrigeration and other industrial institutions and guesthouses, lodges, purchasing malls, business office buildings and other types of civil air-conditioning program.
Package & CZPT
Use CZPT export plywood circumstance with forklift truck feet, easy to load and unload
12-fifteen times to complete the creation after receiving the deposit
CZPT by LCL or FCL
Right after-sales service:
one)
A. twelve months high quality warranty because the day of supply.
B. All extra areas for the equipment can be obtained with agent price from COOLDERE.
C. 24 hrs working mobile phone get in touch with: 13829879662, Electronic mail/ Skype/CZPT manager on the web to assistance.
D. Specialist specialized staff and revenue individual give you with regards to troubleshooting processes via Web and Cellphone any time when needed.
E. Totally free and Expert Education at our Factory under the comfortable problem.
Essential information to Quotation
COOLDERE business have one special engineer staff for design and style, they can make the specific answer according to your functioning need, this sort of as personalize cooling potential, special material for ship use, seawater, corrosive, food sector, juice and wine method and etc. Just inform us:
A. What is actually your h2o composition? or business
B. What is your temperature range?
C. What is your chilled water stream need?
D. What is the operating ambient?
E. What voltage do you need to have?
1. CZPTing Refrigerants: R22, R407, R134a can be equipped on request
2. Unique voltages: 115V 220V~240V 50 Hz or 60Hz (Single and Three Section) are obtainable then we can decide on the correct chiller for you.