As industrial chiller,this air cooled water chiller of box-sort has the following feathers:
one. CZPT capability:fifty five.3kw
two. Regular circumstances: Chilled waterinlet is 7 degrees, outlet temperature is 12 levels. Ambient dry bulb temperature is 35 degrees.
3. Working assortment: Chilled water inlet temperature nine~20 levels.
4. Input electrical power: 3P-380V-50Hz, Allowable fluctuate voltage: ± 10%, allowable voltage difference in period: ± two%.
five. Take orders for special requirements.
six. Scroll airtight compressor worldwide brand-free of charge maintenance.
seven. CZPTtrical elements and refrigeration components are utilised from world-renowned brand name.
8. CZPT and tough design, with stainless metal drinking water tank and substantial-lift pumps.
nine. Wide selection of variable chilled drinking water temperature to meet up with the industrial needs throughout entire calendar year.
10. Created as an unbiased refrigeration circuit, every compressor corresponding to a single refrigeration circuit.
11. CZPTly pick to use environmentally R407C or R134A refrigerant.
CHILLER, H2o CHILLER, AIR COOLED CHILLER
DSP- | ||||||||||||
Kind | 05ASZ | 08ASZ | 10ASZ | 12ASZ | 15ASZ | 20ADZ | 25ADZ | 30ADZ | 40AQZ | 50AQZ | ||
Nominal cooling ability | kW | 14.4 | 25.five | 29. | 32.seven | forty one.one | 58. | sixty five.4 | eighty two.two | 120.4 | 133. | |
ten4kcal/h | 1.2 | 2.two | 2.5 | two.8 | 3.5 | five. | five.6 | seven.one | 10.4 | eleven.4 | ||
(kW) CZPT energy | 4.7 | seven.three | 9.seven | 10.nine | fourteen.5 | 19. | 22.one | 29.6 | 38.two | forty three.8 | ||
(A) CZPT functioning current | nine.2 | 14. | seventeen.five | 19.three | 26.nine | 34.5 | 39.six | fifty four.two | sixty nine. | 77.three | ||
CZPT | Quantity | one | 1 | 1 | 1 | one | two | 2 | 2 | 4 | 4 | |
(kW) CZPT enter electrical power |
4. | six.1 | 8.1 | nine.1 | 12.4 | sixteen.two | 18.two | 24.seven | 32.4 | 36.four | ||
(A) Rated Recent | seven.seven | 11.6 | fourteen.6 | 16.one | 22.seven | 29.2 | 32.3 | forty five.4 | fifty eight.4 | sixty four.five | ||
Evaporator | Sort | Pipe dry large efficiency heat exchanger | ||||||||||
(L/min) Stream | forty one | 73 | eighty three | ninety four | 118 | 166 | 187 | 236 | 345 | 381 | ||
Interface dimension | DN32 | DN40 | DN40 | DN40 | DN50 | DN50 | DN65 | DN65 | DN65 | DN65 | ||
Condenser | Sort | Performance copper pipe and aluminum foil wing heat exchanger | ||||||||||
Condensation axial fan | Amount of enthusiasts | one | two | two | 2 | 2 | six | six | 6 | eight | 8 | |
(kW) Followers energy | .2 | .five | .nine | one.one | one.one | one.three | 1.7 | 2.7 | three.six | four.four | ||
(A) Functioning existing | .six | 1.2 | one.7 | one.nine | two.3 | 2.eight | 3.five | 5. | six.eight | 7.6 | ||
Chilled drinking water pump | Type | , Substantial performance,minimal sounds centrifugal water pump | ||||||||||
(kW) Enter electricity | .fifty five | .75 | .75 | .75 | one.10 | one.50 | two.twenty | 2.twenty | 2.twenty | three.00 | ||
(mH2) Head | 22 | twenty five | 22 | twenty five | 23 | 22 | 22 | 22 | 22 | 23 | ||
(L) Nominal tank volume | eighty | one hundred fifteen | a hundred thirty | one hundred thirty | 210 | 230 | 250 | 310 | 330 | 370 | ||
Total proportions | (mm) Length | 1050 | 1400 | 1450 | 1450 | 1570 | 1900 | 2000 | 2200 | 2900 | 3100 | |
(mm) Width | seven hundred | 900 | 1000 | a thousand | a thousand | 1200 | 1250 | 1350 | 1500 | 1500 | ||
(mm) Height | 1090 | 1290 | 1410 | 1410 | 1610 | 1550 | 1550 | 1820 | 2000 | 2100 | ||
bodyweight | (kg) CZPT fat | a hundred and eighty | 350 | 450 | 500 | seven hundred | 830 | 1050 | 1250 | 1350 | 1550 | |
(kg) Running weight | 260 | 465 | 580 | 630 | 910 | 1060 | 1300 | 1560 | 1680 | 1920 |