Integral Package deal industrial air cooled drinking water chiller for cooling
one. Description:
Huali air cooled chiller have bundle sort and open up sort, the CZPT device adapt
CZPT or CZPT compressor. With large effiency and power conserving character.
1. CZPT capability:nine.2-142.2kw
2. Voltage: one hundred twenty/220/380V-3PH-50HZ.
three. Refrigerant: R22, R407.R134, R410 optional.
four. Chilled water temperature: Air conditioner use 12/7 deg, industrial use 17/12 deg. Also as for every
customer’s demand to change.
5. Shell and tube sort evaporator and condenser.
2. Programs:
CZPT cooling:
CZPTtroplating, plastic goods, hardware, chemical market, electronics, foodstuff preservation,laser
carving, vacuum coating, ultrasonic cleansing and so on industries.
Chiller that uses substantial successful a effortless cleaning stainless steel heat exchanger, exerts its unique
gain from erosion and filth in electroplating, PCB, oxidization, chemical CZPT,and so forth
weak acid and alkaline problems.
3. Specs:
CZPT Air Cooled Chiller | |||||||||||||
Model HLLA ~ | 03SI | 05SI | 08SI | 10SI | twelve.5SI | 15SI | 20DI | 25DI | 30DI | 40TI | 45TI | ||
Rated CZPT Capacity | ×1000 kcal/h | 7.nine | twelve.8 | twenty.8 | 27.nine | 32.three | 40.8 | 55.seven | 64.7 | eighty one.5 | ninety seven. | 122.3 | |
KW | nine.2 | 14.nine | 24.two | 32.4 | 37.6 | forty seven.4 | sixty four.eight | seventy five.2 | ninety four.eight | 112.8 | 142.two | ||
Input Power (KW) | three.85 | five.fifty five | eight.fifteen | 10.4 | twelve. | sixteen. | 20.1 | 22.5 | 31.2 | 33.seven | 45.7 | ||
Comp. Input Power×Qty. (KW) | two.6 | 4.three | 6.35 | eight.one | 9.3 | 12.five | eight.1×2 | 9.3×2 | twelve.5×2 | 9.3×3 | twelve.5×3 | ||
Chilled Water Pump Power (KW) | .75 | .seventy five | one.one | one.1 | 1.5 | 1.five | 1.five | one.five | two.two | two.2 | two.2 | ||
Comp. Current (A) | 6.8 | 10.5 | fourteen | 17.5 | 20 | twenty five.6 | 33.8 | 37.two | forty nine.8 | fifty five.8 | 72.six | ||
Power CZPT | 3φ-380V-50HZ | ||||||||||||
Safety CZPT | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp. protection, Low & High pressure protection, Low temp. protection, Water flow protection, |
||||||||||||
Number of CZPT Circuit | one | 2 | 3 | ||||||||||
Capacity Control (%) | , 100 | , 50, 100 | , 33, 66, 100 | ||||||||||
Refrigerant | R22 | ||||||||||||
Condenser | Ripple Aluminum Fins around Cooper Pipe | ||||||||||||
Power lnput of Fan (KW) | .five | .five | .seven | one.two | one.2 | two. | 2.4 | two.4 | four. | 3.6 | 6. | ||
Evaporator | Pipe Coil Type | ||||||||||||
Water Side Max Pressure (MPa) | – | 1 | |||||||||||
Dia.of Pipe to Evaporator (inch) | one” | 1-1/2″ | two” | two-1/two” | |||||||||
Chilled Water Flow (L/m) | 26.four | forty two.seven | sixty nine.4 | 92.9 | 107.8 | 135.nine | 172. | 194.eight | 272.2 | 292.two | 408.3 | ||
Evaporator Water Pressure drop (kPa) | – | 17 | 23 | 28 | 30 | 28 | 28 | 32 | 32 | 31 | |||
Running Noise dB(A) | 72 | seventy two | seventy three | seventy five | seventy five | 75 | 75 | seventy five | seventy five | seventy five | seventy five | ||
Tank Volume (L) | 80 | 80 | 180 | one hundred eighty | 180 | a hundred and eighty | 270 | 270 | 270 | 270 | 270 | ||
Total weight (Kg) | 130 | a hundred and seventy | 430 | 480 | 510 | 560 | 840 | 880 | 980 | 1130 | 1280 | ||
Dimension L×W×H | 1000×650×1500 | 1500×1100×2200 | 1500×1180×2200 | 2200×1180×2200 | 3200×1180×2200 |
4. Images